Caution: Do not run the pump against the closed gun for longer than 3 min.
-
Please note that the gear pump and the high-pressure piston pump will heat up.
-
To avoid unnecessary heating of the unit, switch off the gear pump immediately after completing
the lubrication process(es).
Observe the safety instructions.
5
Maintenance and care:
Regularly check the pressure-carrying parts (pressure hose and grease gun) as well as the
current-carrying parts of the pump for any possible damage or wear. Immediately replace any
defective parts with original parts.I
Ordering spare parts:
The following information is required when ordering spare parts:
Type, designation of the ET, order number.
The following maintenance intervals must be observed to ensure trouble-free operation
High-pressure grease gun
High-pressure armoured hose
Hydraulic hose lines
High-pressure grease gun
Testing of portable
electrotechnical consumers
Check for any loose connections
Readability and presence of
information
6
Indications in case of malfunctions:
Symptom
The motor of the
hydraulic gear pump does
not run.
Pump does not deliver
grease.
Unit continuously stops
pumping.
Attention!
When dismantling the nut, only hold it in the area (20mm) directly behind the washer.
MATO
/ Benzstr. 16-24 / 63165 Mühlheim a. Main / Tel: +49(0)6108-906-0 / Fax :+49(0)6108-906-120
GmbH & Co. KG
Before each use
X
X
X
X
X
Possible cause
Mains plug not in socket.
The wiring to the motor is
defective.
The container is empty.
The grease supply is
interrupted.
Suction strainer is dirty
Suction strainer is clogged.
Washer
20mm
Suction
annually
X
X
X
X
½ yearly
X
Remedy
Insert the mains plug into the socket.
Repair by a qualified electrician.
Check the filling level in the container.
Bleed the pump.
Clean suction strainer
Clean the suction strainer.
Nut
According to
manufacturer
X
X
X