Heated boiling
This mode allows keeping the selected temperature (40-90°С) for up to 2 hours. If
the temperature will drop lower than the selected value, the heating element will
be automatically enabled.
1. Press
. The heating process will start, 100°С indicator will appear on the top
of the display.
2. Press
button during water heating. The button indicator will start blinking.
The heating temperature value will be flashing on the top of the display. The
current temperature value of water is displayed at the bottom of display.
3. Use «+» и «–» buttons to adjust the temperature value if necessary (in 5°С in-
terval). It can also be adjusted while the kettle is in the heating mode. In a few
seconds after the end of adjustment the temperature value on the top of display
will switch to 100°С.
4. After water comes to a boil an audible signal will be heard and appliance will
switch to the heating mode. The temperature value indicator and
display will be lit up solid in this mode, and also
5. The appliance will automatically switch to standby mode in 2 hours.
6. To interrupt the boiling and switch to the heating repress
the heatign after boiling repress
button. To interrupt the operation remove
the kettle from the base.
Safety system
• The kettle is equipped with the system of auto shut-off upon boiling or
removing from the base.
• In case of lack of water in the kettle or water shortage the automatic
overheat protection will be activated. An audible signal will be heard and
the appliance will be automatically disconnected.
will be displayed. To enable indication remove the kettle from the base.
Wait till it completely cools down. Then the appliance will be ready for
operation.
Control panel lock
To provide extra safety the appliance is equipped with control panel lock function.
It prevents accidental pressing the buttons. To enable/disable the lock in the
standby press «+» button, and, holding it, press
heard. If any button is pressed in the lock mode, «+» and
be lit on the control panel.
Non-volatile memory
The kettle is equipped with a non-volatile memory unit. In case temporary power
cut occurs during water heating or boiling all user's settings are saved to the
memory of the appliance. When power supply is resumed the kettle will automati-
cally continue its operation.
III. CLEANING AND MAINTENANCE
Unplug the kettle and allow it to cool before cleaning.
Base and body cleaning
on the
Clean the kettle body and base with a soft cloth. Dry the kettle before operation.
indicator will be lit.
button. To disable
Descaling
During operation, depending on the composition of usable water, oxide spots and scale
can appear on the heating element and inner walls of the appliance. To remove them:
1. Pour water into the kettle ¾ from maximum capacity and bring it to a boil.
2. After the kettle turns off, add 8% acetic acid solution to the maximum level on
the inner surface of the body.
3. Leave this solution inside the kettle for several hours.
4. Empty the kettle and rinse properly.
and
indicators
5. Fill the kettle with clean water up to the maximum level on the inner surface
of the body and bring it to a boil.
6. Empty the kettle and rinse it again. If scale still remains, repeat the procedure
mentioned above.
You can also use special means for descaling. Follow the manufacturer's instructions
in this case.
To clean removable scale filter
button. An audible signal will be
button indicators will
1. Open the lid. Remove the filter pulling it upward.
2. Rinse the filter. You can use a dishwashing solution.
3. Place the filter into the kettle with the projection to the centre.
DO NOT use a sponge or tissue with hard or abrasive surface or abrasive pastes. Do not
use any chemically aggressive substances or any other agents which are not recom-
mended for cleaning items that come into contact with food.
ATTENTION! Before repeated usage make sure that the electrical contacts are kept dry!
ATTENTION! Never immerse the kettle, the base, the power cord or the socket in water:
the electrical contacts should not contact with water.
GBR