For optional pump.
Power supply: AC230V/50Hz, <500W
Recommended part: Yonos 25/6: made by Wilo
•
For optional mixing valve.
Power supply: AC230V/50Hz (input open/output close)
Operating time: 30s~120s
Recommended part: 167032: made by Caleffi
This section is for authorized and licensed electrician/water system
installer only. Work behind the front plate secured by screws
must only be carried out under supervision of qualifi ed contractor,
installation engineer or service person.
Network Adaptor 6 Installation (Optional)
1. Remove the Control Board Cover 5, then connect the cable
included with this adaptor to the CN-CNT connector on the
printed circuit board.
•
Pull the cable out of the Tank Unit so that there is no pinching.
•
If an Optional PCB has been installed in the Tank Unit, connect
to the CN-CNT connector of the Optional PCB.
2. Insert a fl at head screwdriver into the slot on the top of the
adaptor and remove the cover. Connect the other end of the
CN-CNT cable connector to the connector inside the adaptor.
Slot
20
WARNING
Connector
3. Pull the CN-CNT cable through the hole in the bottom of the
adaptor and re-attach the front cover to the back cover.
4. Fix the Network Adaptor 6 to Network Adaptor Holder.
Guide the cable as shown in the diagram so that external forces
cannot act on the connector in the adaptor.
Connection examples:
CN-CNT cable
Without Optional PCB
With Optional PCB
CN-CNT cable
(Take care not to
pinch the cable)
Network
Adaptor
Holder
CN-CNT cable
Network
Adaptor
Holder