37. Sterilization
Initial setting: 65°C 10min
Set timer to perform sterilization.
1 Set operating day & time. (Weekly timer format)
2 Sterilization temp (55~75°C  If use back-up heater, it is 65°C)
3 Operation time (Time to run sterilization when it reached setting temp
5min ~ 60min)
User shall set whether to use or not to use sterilization mode.
3-5. Service Setup
38. Pump maximum speed
Normally setting is not necessary.
Please adjust when need to reduce the pump sound etc.
Besides that, it has Air Purge function.
When *Pump fl ow setting is Max. Duty, this duty set is the fi x pump duty run
during room side operation.
39. Pump down
Operate pump down operation
40. Dry concrete
Operate concrete curing operation.
Select Edit, set temp for every stage (1~99 1 is for 1 day).
Setting range is 25~55°C
When it is turned ON, dry concrete starts.
When it is 2 zone, it dries both zones.
41. Service contact
Able to set name & tel no. of contact
person when there is breakdown
etc. or client has trouble. (2 items)
3-6. Remote control setup
42. RC selection
Set to "Single" when only one remote controller is installed.
Set to "Dual" when two remote controllers are installed.
Initial setting: Depend on model
Service setup
Pump down:
Service setup
Service contact:
Select
Initial setting : Single
12:00am,Mon
ON
Confi rm
40°C
35°C
30°C
1
2
12:00am,Mon
Contact 1
Contact 2
Confi rm
①  ③
Service setup
Flow rate
Max. Duty
88:8 L/min
0xCE
Select
Service setup
Pump down operation
Pump down:
in progress!
ON
OFF
45°C
40°C
35°C
3
5
6
4
Contact-1: Bryan Adams
ABC/ abc
A B C D E F G H I J K L M N O P Q R
S T U V W X Y Z
a b c d e f g h i
j k l m n o p q r s t u v w x y z
Select
RC selection
Single
Dual
Select
Confi rm
12:00am,Mon
Operation
Air Purge
17:26, Wed
Confi rm
Stage
0-9/ Other
Enter
12:00am,Mon
33