Remove Functional Part; Fault Correction - Franke AQRM460 Instrucciones De Montaje Y Uso

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 13

11. Remove functional part

11.1 Remove the sealing cap (siehe
11.2 Close the flow volume regulator.
11.3 Remove the safety ring.
11.4 Remove the pressure cap and spring.
11.5 Use a socket spanner to unscrew the functional part.
11.6 Reassemble in the reverse order.

12. Fault correction

Fault
Water does not flow at
all
Water flows conti-
nuously
Water flow too weak
Water flow too large
If you are unable to correct a fault or if the fault is not described in the fault correction
section, please inform the AQUA service department.
6
Kapitel
Cause
– Water supply interrupted
– Flow volume regulator closed
– Functional part faulty
– Functional part/upper section faulty
– Flow volume regulator not fully
opened
– Supply pressure too low
– Flush volume adjustment incorrect
– Flush volume adjustment incorrect
10.1).
Remedy
➯ Restore
➯ Open it
➯ Replace it
➯ Replace it
➯ Open it
➯ Check it
➯ Adjust it
➯ Adjust it