Weekly timer setting function: The electric fireplace has the
programming function of weekly timer on/off time setting. Edit
weekly timer on/off time.
Switch key of weekly timer setting function for power-on
time and power-off time setting
Room temperature display error correction function:
When in use the heater, if the heater display the room
temperature with the actual room temperature have error, you
can use the temperature display error correction function to
change the display window room temperature, through long time
press TIME key on the keypad by 3 seconds, then the display
window of room temperature normally light change to
temperature correction display, The digital display is in the
flashing display mode. When the first time used the temperature
error correction function, Press the TIME button for 3 seconds,
and the display window will be displayed as 0. At this time, every
time you press the up or down key of the remote control, the
display window will be up +1 or down -1 accordingly, and the
correction range is between -9 and 9. If on the temperature
error correction mode, 10S no operate of the keypad or remote
control,
then the display window will be turned back to the
room temperature display mode.
Screen protection function:
Temperature Limiting Control
This heater is equipped with a Temperature Limiting Control.
Should the heater reach an unsafe temperature, the heater will
automatically turn OFF. To reset:
1.Turn the ON/OFF switch on the CONTROL PANEL to
OFF. Wait 5 minutes.