Descargar Imprimir esta página

Kübler Codix 521 Manual De Instrucciones página 10

Ocultar thumbs Ver también para Codix 521:

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

selecting "Yes", to exit the programming
menu and to take over (store) the new values.
If "no" is selected, the programming routine
is repeated, the latest values set remaining
active. They can now be checked again or
modified.
3. Programming routine
The first menu item is the selection of the basic
operating mode, which determines the functions
of the device.
Operating mode pulse counter.
Continued in point 4. of Codix
521 on page 2
Operating mode frequency
meter. Continued in point 4. of
Codix 522 on page 4
Operating mode time meter.
Continued in point 4. of Codix
523 on page 6
Pulse counter/Po si ti on indicator
Codix 521
(Codix 524: Operating mode pulse counter)
1. Description
• 6-digit display counter with SET/RESET-function
• Red LED display, character height 8 mm
• Display range from -199 999 to 999 999
• Leading zeros suppression
• Programming via two setting keys on the front
side
• During programming, the display guides the
user with text prompts
• Counter operating modes:
Count input INP A + count direction input
INP B (Cnt.Dir)
Differential count INP A – INP B (up.dn)
Totalising INP A + INP B (up.up)
Count Up/Down INP A 90° INP B x 1 (quAd)
Count Up/Down INP A 90° INP B x 2 (quAd2)
Count Up/Down INP A 90° INP B x 4 (quAd4)
• Optional optocoupler output
2. Inputs
INP A
Dynamic count input.
INP B
Dynamic count input.
Page 2
SET/RESET
Dynamic SET/RESET input. Linked in parallel to
the red SET/RESET key. Resets the counter to
the predefined setting value.
3. Optocoupler output
Active if count value < 0. Simple preset counter
can be realized, when using subtract mode.
4. Programming routine
The programmable parameters of the device are
described below, in the order in which they can
be set. The device is fully programmed after one
pass of the routine.
The first values stated correspond to the
factor settings.
4.1 Polarity of the inputs
npn: switching for 0 V
pnp: switching for +U
4.2 Switching on the 30 Hz filter
(INP A, INP B)
The filter provides input
damping*
30 Hz filter off (f
30 Hz filter on
4.3 Input mode
Count input and count direction
input
INP A: Count input
INP B: Count direction input
Differential input
INP A: count input adding
INP B: count input subtracting
Totalising
INP A: count input adding
INP B: count input adding
Quadrature input
INP A: count input 0°
INP B: count input 90°
(optional)
B
)
max
www.kuebler.com

Publicidad

loading

Este manual también es adecuado para:

Codix 522Codix 523Codix 524