Quadrature input with pulse
doubling
INP A: count input 0°
INP B: count input 90°
Each pulse edge of INP A will
be counted
Quadrature input with pulse
quadrupling
INP A: count input 0°
INP B: count input 90°
Each pulse edge of INP A and
INP B will be counted.
4.4 Multiplying factor
It can be set from 00.0001 up
to 99.9999.
The decimal point is set to 4
decimal places.
„0" is not accepted!
4.5 Dividing factor
It can be set from 00.0001 up
to 99.9999.
The decimal point is set to 4
decimal places.
„0" is not accepted!
4.6 Decimal point
The decimal point defines the
way of displaying the count val-
ues. It does not affect counting.
0
0.0
0.00
0.000 three decimal places
4.7 SET/RESET Mode
manual reset via the red SET/
RESET key and electrical reset
via the SET/RESET input
no reset (red SET/RESET key
and SET/RESET input locked)
only electrical reset via the
SET/RESET input
* where bounce occurs, e.g. with contacts
www.kuebler.com
no decimal place
one decimal place
two decimal places
only manual reset via the red
SET/RESET key
4.8 SET value
The device will be set to the set
point by pressing the red SET/
RESET key or activating the
SET/RESET input.
SET value -199999...999999
(number of decimal places
depends on the decimal point
option)
For programming the decimal point see 4.6
4.9 End of programming
The programming routine is
repeated once more. The
values set until now can be
checked and modified.
The programming routine will
be left and all values set will be
stored as new parameters.
Afterwards the device is ready
for operation.
Tachometer/Frequency meter Codix 522
(Codix 524: Operating mode frequency meter)
1. Description
• 6 digit frequency meter
• Red LED display, character height 8 mm
• Display range from 0 to 999 999
• Leading zeros suppression.
• Programming via two setting keys on the front
side
• During programming, the display guides the
user with text prompts
• Value conversion and display in 1/s or 1/min
• Optional optocoupler output
2. Inputs
INP A
Dynamic count input.
3. Optocoupler output
Active at f=0. Can be used e.g. to activate a „No
operation" lamp.
(optional)
Page 3