Descargar Imprimir esta página

PEDROLLO TISSEL-100 Instrucciones Originales De Uso página 25

Variador electrónico de frecuencia

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 40
TECHNICAL DATA
• Supply voltage: 230+/-10% V single phase
• Outlet voltage: 230 V three-phase
• Frequency: 50-60 Hz
• Level of protection: IP 65
• Vertical work position, with entrance of liquid from below and exit from above.
ATTENTION: in the presence of a low voltage (nominal value -10%) there may be power surges at the start and at
maximum power
POWER AND ABSORPTIONS
Model
V in
TISSEL-100 (7 A)
1 ~ 230 V
TISSEL-100 (12 A) 1 ~ 230 V
SELF-LIMITATION DUE TO OVERLOAD
If the current recorded by the inverter or the temperature of the components of the inverter exceed the safety limits TISSEL-100
starts a progressive reduction in the frequency of operation until the values exceeding the limits return to normal.
ILLUMINATED SIGNS
ON
OFF
FLASHING
V out
A out
3 ~ 230 V
7
3 ~ 230 V
12
TISSEL-100 does not detect a power supply.
ATTENTION: the absence of a power supply is not guaranteed, the card could
be damaged but still live.
TISSEL-100 is live but the pump is not running (STAND-BY)
TISSEL-100 is live and the pump is running
TISSEL-100 is live but OUT OF SERVICE (or in TEST), restoration is only manual
TISSEL-100 is in a state of alarm, restoration is only manual
Fuse (A)
P2 max (kW)
20 (6x32)
1.1
25 (6x32)
2.2
P2 max (HP)
1.5
3.0
ENGLISH |
25

Publicidad