PEDROLLO TISSEL-100 Instrucciones Originales De Uso página 33

Variador electrónico de frecuencia

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 40
DISPLAY
PARAMETERS
RAPIDITY OF
RF 4
INVERTER REACTION
FREQUENCY OF
FS 10
COMMUTATION OF
THE MODULE
ANTI-BLOCKAGE
US 0
START-UPS
ENTRANCE SIGNAL
EI 0
EXIT SIGNAL
EO 0
Max 2 A @ 250 Vac
Max 1 A @ 30 Vdc
RECYCLING
AI 60
FUNCTION (min)
RECYCLING
AT 10
ACTIVATION TIME
LINE OF INVERTER
W NC
LINE VOLTAGE (V)
V 230
DESCRIPTION
Sets the rapidity of response of the inverter
to changes in pressure; the rapidity of the
responses depends on the characteristics
of the facility.
Sets the frequency of commutation of
the power module. In the case of a long
power cable without a sinusoidal filter
this frequency must be reduced to the
minimum value.
Sets the interval between two successive
automatic "anti-blockage" start-ups (for
long periods of inactivity); setting the
value at "0" the function is disabled.
Sets the FUNCTION of the incoming signal
(of the clean contact type , NO or NC)
El = 0: no function, the state of the entrance is ignored
El = 1: entrance level signal (NC)
El = 2: start and stop by external signal (NC)
El = 3. Passage to the 2nd SETPOINT of pressure (NC)
El = 4: entrance external flow signal (NC): substitutes the signal coming from the
non-return valve
El = 5. Entrance alarm reset signal
Sets the FUNCTION of the exit signal (of the
clean contact type, NO or NC)
EO = 0: no function; the relay has not been activated
EO = 1: alarm sounds; the relay is activated if the inverter alarm is set off
EO = 2: pump switched on: the relay is activated if the pump is switched on
EO = 3: recycling function; activates the exit relay at time intervals defined by the
Al parameter
Sets the intervals of activation of the exit
signal (of the clean contact type) and it is
active if E0 is set at value 3
Sets the intervals of activation of the exit
signal (of the clean contact type)
Activates the communication between two
or more inverters
defining the task of each unit: MS (MASTER
Unit), S1/S2 (SLAVE units), NC (operation
with a single inverter)
Defines the supply voltage
230 V for single-phase powered versions
400 V for three-phase powered versions
u.m. Default Min
Max
-
3
1
5
kHz
8
4
12
min
0
0
999
Values of the parameter
-
0
0/ 1/ 2/ 3/ 4/ 5
Values of the parameter
-
0
0/ 1/ 2/ 3
min
60
1
999
sec
10
1
999
Values of the parameter
-
NC
NC/ MS/ S1/ S2
V
-
-
-
ENGLISH |
Step
1
2
1
1
1
-
Follows
33