• Provide upstream of the mains supply of the
automation a device that can assure an all-
pole disconnection from the electrical grid
(with the 3rd category of overvoltage and with
an opening distance of the contacts in each
pole of at least 3 mm), in compliance with the
installation rules and directly connected to the
power supply terminals.
5.1 SETTINGS AND CONNECTION OF ACCESSORIES
5.1.1
CONTROL AND ADJUSTMENT PANEL REFERENCES
230V ~ mains power supply fuse (F3.15A250V).
F1:
F2:
24V
operator power supply fuse (F15A250V).
FORCE (TR1):
FORCE control (clockwise for maximum force).
AUTO (TR2):
Auto closing time (time increase in clockwise
direction).
P1:
Remotes acquisition button.
P2:
Maximum travel learning button.
S1: Auto (open-close) or step-by-step mode (open-stop-close) key selector
switch.
S2: Key selector switch to invert motor sense rotation
POWER LED: 2W LED courtesy light.
LED1:
Power indicator LED (feedback).
LED2:
Maximum travel programming indicator LED (feedback).
LED3:
Remotes save/delete indicator LED (feedback).
5.1.2 ACCESSORIES CONNECTION TERMINALS (CN1)
1: GND (common).
2: Open/Close Pushbutton input (NO).
3: Stop Pushbutton input (NC).
4: Photocells Safety Input (NC).
5: 24V
+ Power Supply for Photocells Safety (max 300mA).
6: 24V
– Power Supply for Photocells Safety.
7: 24V
+ Power Supply for Flashing Light (max 5W).
8: 24V
– Power Supply for Flashing Light.
9: Antenna Input (signal pole).
10: GND (common).
11: 8K2 Safety Input.
5.1.3 MAXIMUM TRAVEL LEARNING (OPENING LIMIT SWITCH)
To set the Opening Limit Switch the operator must be coupled to the door
via the track and the sliding runner must be attached to the drive chain or
belt. In addition, at least one pushbutton control must be connected to the
system (or a saved remote must be available) and activated secutiry devices
(photocells and STOP enter) and N.C. (normally closed) To acquire the
Opening Limit Switch position: power the operator, bring the door to
a "nearly closed" position (approximately 500 mm from the closing
stop) by means of the pushbutton or button on the remote. Press and hold
down button P2 on the control panel until LED2 comes on; release button
P2 (LED2 starts blinking). The door will perform a closing movement until
reaching the end stop. Once the door is closed (Zero position acquisition) it
will start the opening movement at low speed; when the door reaches the
required opening position (Opening Limit Switch) press P2 again: the door will
stop in the fully open position (maximum travel). Alternately, you can allow the
door travel to reach the mechanical end stop (if fitted in the guide track) and
still acquire the Opening Limit Switch position. The operator will subsequently
perform an automatic closing cycle, LED2 will stop blinking and then switch
off, thereby confirming that the maximum travel position has been saved.
The Opening Limit Switch acquisition procedure can be repeated, if
necessary, only with the operator powered in the stop position.
5.1.4 SAVING / DELETING A REMOTE
To save a remote (Comunello radio transmitter) simply press button P1 on the
control panel. Management logic is as follows:
Channel 1: Press button P1 once, LED3 blinks once. Press the remote
button to which you wish to assign the OPEN-CLOSE function.
Channel 2: Press button P1 twice, LED3 blinks twice. Press the remote
button to which you wish to assign the STOP function.
Reset:
Press button P1 four times, LED3 will switch on steady.
Press and hold down button P1, LED3 blinks rapidly; keep
button P1 pressed until LED3 stops blinking (confirmation that
18
COMUNELLO ®Copyright 2018 - All rights reserved
the saved remotes have been deleted).
5.1.5 AUTOMATIC CLOSING
The operator features a selectable Automatic Closing function. To
enable or disable Automatic Closing set the Trimmer TR2 as follows:
AUTO CLOSING TIME SELECTION
0%
= Auto closing disabled
50%
= 3"
75%
= 30"
100% = 60"
Note= Increase in clockwise direction
Factory setting: Automatic Closing enabled.(30")
5.1.6 AUTOMATIC OR STEP-BY-STEP MODE
There are two movement control modes available: Automatic Mode
(each time the Open-Close button or Remote button is pressed the
operator reverses its direction of run) or Step-by-Step (each time the
Open-Close button or Remote button is pressed the operator performs
the Open-Stop-Close-Stop movement in sequence). Set the required
operating mode with selector S1:
S1 ON
Step-by-Step Mode enabled
S1 OFF
Automatic Mode enabled
5.1.7 FORCE ADJUSTMENT
The operator Force can be adjusted using trimmer TR1. Turning the
trimmer clockwise increases driving force (by turning the trimmer counter
clockwise it decrease and the system becomes more sensitive to the
obstacle detection). Factory setting: Minimum Force.
5.1.8 8K2 SECURITY DEVICE INPUT (M10-M11)
The 8K2 safety device input allows the use of 8k2 resistive safety edges
which brefely reverse the movement both when opening and closing (it
remains in standby until a given input).
ATTENTION: During the programming phase, the control unit checks the
type of maximum impedance at the input of terminal 8k2-GND (for ex. N.O.,
N.C. or 8k2 ohms) and manages the safety device accordingly. At the end
of the stroke programming, always check the correct activation of the input
of the connected safety device.
5.1.9 PHOTOCELL INPUT (M1-M4)
The entrance of the photocell safety device manages a photocell (N.C.)
which activates during closing, carrying out total inversion of the movement
(and preventing closure).
In the closed door position, if the photocell is intercepted, it prevents
opening (obstacle detection when closed)."
5.1.10 OBSTACLES DETECTION
The operator is equipped with a system for the detection of obstacles
during its normal travel movements. By means of a digital encoder, when
the normal travel of the door is obstructed the operator is stopped once
the impact force prescribed by the applicable standards is exceeded;
the operator then performs a short reverse movement and remains in
STOP status until it receives a new command.
NOTE= the control system has a periodic autoregulation of obstacle
intervention threshold profiles In order to make up for the possible
progressive loss of balancing of the structure.
5.1.11 COURTESY LIGHT
The operator is equipped with an internal LED courtesy light (2W,
steady on) that switches on with each movement and remains on for
approximately 30 seconds after the Open (or close) and 60 sec after
every closing (total). This function is always on and cannot be overridden.
5.1.12 EXTERNAL FLASHING LIGHT/INDICATOR LIGHT
If an external flashing light or indicator light is required, use the dedicated
power supply terminals (Control panel: M7-M8). These terminals provide
a dc output (28V
) with maximum current draw of approximately
150mA.
NOTE: The output voltage is constant and can therefore be used to
power a suitably rated indicator light. If a flashing light is to be connected
it must be of the self-flashing type (SWIFT).