Descargar Imprimir esta página

SOMFY ilmo 40 WT Instructions página 29

Ocultar thumbs Ver también para ilmo 40 WT:

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 33
2. 1. 4. Installing the drive/tube assembly
Install and fix the tube/drive assembly onto the end
1)
bracket f and onto the drive bracket g:
Ensure that the drive/tube assembly is secured onto
the end bracket. This operation prevents the drive/
tube assembly from coming out of the end bracket
mounting when the roller blind reaches the lower end
limit position.
Depending on the type of bracket, screw the adapter
2)
onto the motor head.
2. 2. WIrIng
Cables which pass through a metal wall must be protected and isolated using a sheath or
sleeve.
Attach cables to prevent any contact with moving parts.
If the motor is used outdoors and if the power supply cable is of the H05-VVF type, then
run the cable in a UV-resistant conduit, e.g. trunking.
The cable for the Ilmo 40 WT cannot be removed. If it is damaged, return the drive to the
After-Sales department.
Leave the drive power supply cable accessible: it must be possible to replace it easily.
Always make a loop in the power supply cable to
prevent water entering the drive!
The ilmo 40 WT is a Class II drive; it has no earth
wire.
Switch off the power supply.
-
Connect the drive according to the information in the table
-
below:
230 V
50 Hz
it is possible to wire several motors to the same control point by following the formula:
Number of motors which can
be connected in parallel
Copyright © 2009- 2014 Somfy SAS. All rights reserved.
5061937C003_ilmo_40_WT.indb 27
Cable
Neutral (N)
Live (L1)
Blue
Brown
Cut-off power of the control point
(A) x 0.7
Motor consumption (A)
(see motor label)
1)
g
2)
h
off
n
l1
Live (L2)
230 V
Black
Images not contractually binding
L1
EN
L1
f
l2
50 Hz
27
24/10/2014 10:22

Publicidad

loading