►►17.TROUBLESHOOTING
FAULTS
The heater
No voltage
doesn't work
Incorrect connection of
the room thermostat
The heater
Tripped room
doesn't work in
thermostat (optional
heating mode
item)
Incorrect connection of
the room thermostat
Room thermostat
socket cap not
inserted properly
No gas supply
Blocked heater
Defective electronic
equipment
Incorrect heater setting 1.Authorised technical support centre
The flame
Defective electronic
does not stay
equipment
on
The flame
Tripped room
turns off
thermostat (optional
during normal
item)
operation
No gas supply
No voltage
The heater overheats
CAUSES
1.Check the mains system
2.Check the electrical connections
3.Authorised technical support centre
1.Connect the room thermostat correctly
1.Set the room thermostat at a temperature
lower than the room thermostat
1.Connect the room thermostat correctly
1.Insert the cap properly in the socket
1.Check the gas system
2.Authorised technical support centre
1.Reset the heater by setting the power
button to position "0"
2.Authorised technical support centre
1.Authorised technical support centre
1.Authorised technical support centre
1.Set the room thermostat at a temperature
lower than the room thermostat
1.Check the gas system
2.Authorised technical support centre
1.Check the mains system
2.Check the electrical connections
3.Authorised technical support centre
1.Clean the air inlet (lower side) and reset
the manual security thermostat (Fig. 27)
2.The heater's limit operating temperatures
are too high
3.The air intake temperatures are too high
4.Extensive exposure to sun light
5.Authorised technical support centre
SOLUTIONS