Installation using the Intrinsically Safe Barrier
WARNING! The instructions on this page are intended as an introduction to
the proper wiring procedure for the Series 900CDP Digital Meter. Detailed wiring
instructions and information are included in the 4 page document labeled:
"FILL-RITE SERIES 900DP METER, INTRINSICALLY SAFE FLOWMETER"
(control drawing DC000675-000), included in the box with your meter. These
instructions MUST BE READ AND UNDERSTOOD COMPLETELY PRIOR to
installation. See "WARNING" under "Electrical Installation Information" on page
10 and 11 prior to beginning installation.
WARNING! Substitution of components will impair intrinsic safety!
WARNING! To prevent ignition of combustible or flammable atmosphere,
disconnect power before servicing.
WARNING! To prevent ignition of flammable or combustible atmosphere, do not
use a volt meter or similar powered tools during live maintenance.
WARNING! Intrinsically Safe Barrier must be housed in a environmentally
safe container.
A
B
C
The Intrinsically Safe Barrier is designed
to work with the following incoming power
sources:
90 - 240 VAC, 50 - 60 Hz
(US: 120 VAC, 60Hz, Load Neutral Ground)
(EU: 230 VAC, 50Hz, Load Neutral Ground)
A) Output to Meter
Power: +
Power: -
Pulser Signal
B) Output to FMS
1 - Output
2 - Unused
3 - Output
C) AC Power Input
Line
Ground
Neutral
D) DC Power Input
DC+
DC-
D
12
12 - 40 VDC
or