IMPORTANT! When the meter is in the "Deep Sleep" mode, dispensing fluid will
NOT turn the meter on. The meter will not display or accumulate any fluid that is
dispensed while in "Deep Sleep" mode.
• Pressing any button will turn the meter
on when in deep sleep mode (fluid flow
will not turn the unit on or cause it to exit
deep sleep mode).
• The last count and selected totalizer is
retained and displayed when the meter
is turned on.
• Pressing and releasing the TOTAL
button will switch between the resettable
and non-resettable totalizers. (The "R"
icon will be displayed when the
resettable total is displayed).
• Pressing and holding the RESET button
for 2 seconds will reset the counter.
• Pressing and holding the RESET button
and TOTAL buttons for 2 seconds will
reset the totalizer. The resettable totalizer must be active in order to reset it.
• Pressing and holding the RESET button and CAL buttons for 2 seconds will display the
software version for 2 seconds and then perform a segment check for 3 seconds, and
then restore the display.
• Pressing and holding the CAL button for 5 seconds will place the meter into a deep sleep
mode.
IMPORTANT! "Deep Sleep" mode is designed to maintain a status of operational
readiness while offering battery conservation. The meter should be placed in this
mode under the following circumstances:
• Flushing the unit so the dispensed volume is not counted.
• Traveling over rough surfaces (off-road); fluid in the metering chamber will be
counted if fluid is being jostled.
• Extending battery life; the meter can be placed in deep sleep mode repeatedly
with no adverse effect on battery life.
• After 30 seconds of inactivity, the display will blank to conserve battery power.
• If the meter is connected to the external power source, the display will not blank unless
forced into deep sleep mode.
• If external power is removed, the meter will automatically switch to battery only operation
and vice-versa.
• The counter and resettable totalizer 2 can be reset even if fluid flow is detected. The
meter will continue counting during the 2 second RESET button press, reset to 0, and
resume counting.
Low Battery Warning
The digital display includes a "Low Battery"
warning indicator. When the batteries
reaches a level low enough to require
replacement, the display will show "BAT"
as a reminder to change them. Replace
batteries when indicated per procedure on
page 8.