Descargar Imprimir esta página

Tuthill FILL-RITE 900CDP Serie Manual De Instalación, Operación Y Seguridad Del Propietario página 14

Medidor digital de líquido

Publicidad

Idiomas disponibles

Idiomas disponibles

Reed Switch Information (cabinet models only)
WARNING! CONDITIONS FOR SAFE USE: The Remote Reed Switch Assembly
Part No. SA000048-005 is provided with a non-metallic housing. Care must be
taken to avoid ignition hazards due to potential electrostatic charging hazard.
Technical Specifications and Information
Dimensions: 6.75" (H) x 8.46" (W) x 4.10" (D)
Accuracy: ± 1.25 %
Repeatability: ± 0.25% at calibrated flow rate.
Flow Rate: 6 to 40 GPM (22.7 to 151.4 LPM)
Pressure Rating: 50 psi (3.5 Bar)
Construction: Aluminum
Units of Measure: Ounces, pints, quarts, liters, gallons, 1 special "unit of measure" option.
Counter: 4 digit resettable counter; (.01 – 9999 units).
Totalizers: 7 digit non-resettable "Master" totalizer, 7- digit resettable secondary.
Mounting Options: Can be installed for vertical or horizontal mounting by rotating display
accordingly.
Power Supply: 2 "AA" batteries (Dura-cell MN1500, MX 1500, or Energizer E91 Alkaline
batteries only); optional external power through Intrinsically Safe Barrier.
Expected Battery Life: 2 – 4 years of normal use with standard Alkaline batteries.
Operating Temperature Range: -40° to 60° C (Pulser units have face heat for extended
use down to -40°; note that display goes blank below -40° but meter and pulser will contin-
ue to operate normally).*
*See Specific Conditions of Use on page 15.
14

Publicidad

loading