EN: Installation Sheet
Introduction
The EV1000 series includes models EV1012 and EV1012AM.
These detectors have a patented mirror, pyro, and signal
processing technology.
WARNING!
The equipment is not earthed. Any
external circuit connected to the equipment must be
located within the same building and connected to a
protective earthing conductor.
Wire insulation of cables connected to the equipment must
conform to IEC 60332-1-2 and IEC 60332-1-3 or IEC 60332-
2-2, depending on the wire cross sectional area, or IEC TS
60695-11-21, regardless of cross sectional area. Alternatively,
such wires must comply with UL 2556 VW-1.
Installation guidelines
The technology used in these detectors resists false alarm
hazards. However, avoid potential causes of instability such as
(see Figure 1):
•
Direct sunlight on the detector
•
Strong draughts onto the detector
•
Heat sources within the detector field of view
•
Large animals within the detector field of view
•
Obscuring the detector field of view with large objects,
such as furniture
•
Objects within 50 cm (20 in.) of the anti-masking (AM)
detector
P/N 146169999-10-ML • REV N • ISS 19JUL22
9A
9B
6
(2)
9A
1A
3B
7B
6
4
5B
(3) 5 curtains
6 m range
1B
2B
•
Installing two detectors facing each other and less than
50 cm (20 in.) apart
Installing the detector
Figure 7
(1)
Standard connection (factory default)
(2)
Dual loop connection
CP
Control panel
WT
Walk test
AM
Antimasking
D/N
Day/night
Rtest
Remote test
To install the detector:
1.
Lift off the custom insert and remove the screw
(see Figure 2, item 1).
2.
Using a screwdriver, carefully prise open the detector (see
Figure 2, items 2 and 3).
3.
Fix the base to the wall. For flat mounting use a minimum
of two screws (DIN 7998) in positions A. For corner-
mounting use screws in positions B or C (Figure 3). To
install a pry-off tamper, use position A or B.
4.
Wire the detector (see Figures 3 and 7).
5.
Select the desired jumper and DIP switch settings (see
Figure 5). See "Jumper settings" on page 4 for more
information.
6.
Remove the blinders and add the stickers, if required. See
"Configuring the coverage pattern" on page 5 for more
details.
(4) 7 curtains
6 m range
(6) 7 curtains
12 m range
(5) 5 curtains
12 m range
(7) 9 curtains
12 m range