SW 4: Signaling AM or TF output
On: Signals AM on both the AM and Alarm relays. Signals TF
on the AM relay only (EN 50131).
Off: Signals AM and TF on the AM relay (default).
SW 5: Setting LEDs
On: Enables both LEDs on the detector at all times (default).
Off: Puts both LEDs under the control of the Walk Test and
Day/Night input. This activates the memory feature of the
detector.
AM calibration
During start-up the AM circuitry calibrates itself to its
environment. It is important to make sure that there are no
changes made to the environment within 1 m distance of the
detector within 60 s after powering up, otherwise the detector
may be vulnerable to false AM alarms and these alarms may
be impossible to reset.
Configuring the coverage pattern
Remove blinders (Figure 8, item 1) if necessary. The
modified pattern is shown in Figure 8, items 3 to 7.
Note:
If both blinders are installed, the detector range is
limited to 6 m (default).
Modify the pattern by breaking out blinder parts (shown as
gray in Figure 8, item 1). The corresponding curtain
fragments are shown in Figure 8, item 2.
Put the appropriate mirror stickers if necessary. See
Figure 6, item 1 for details.
Caution:
Removing stickers can damage the mirror
surface.
When near objects directly under the detector, fit the mask
to the inside of the window (default). This disables the part
of the curtains looking down at the object, whose
closeness might destabilize the detector. See Figure 6,
item 2.
LED indication
PIR
Red LED
Alarm relay
Start up
Closed
Low voltage
Open (Alarm)
PIR intruder
Open (Alarm)
alarm
Red
Yellow
PIR/AM
LED
LED
Start up
Low voltage
PIR intruder
alarm
Latched PIR
(Memory)
AM alarm
P/N 146169999-10-ML • REV N • ISS 19JUL22
To reset
Automatically after 25 s
Apply correct voltage
Automatically after 3 s
Alarm
AM
To reset
relay
relay
Closed
Closed
Automatically
after 60 s
Open
Open
Apply correct
(Alarm)
(Alarm)
voltage
Open
Automatically
(Alarm)
after 3 s
Switch to Night
mode
Open*
Open
See DIP
(Alarm)
(Alarm)
switch 3
PIR/AM
Red
Yellow
LED
LED
After AM
reset
Technical
fault
* Depends on the setting of the DIP switch SW4.
Continuously on
Normal blinking (1 Hz)
Specifications
Detector
Signal processing
Range
Optical
Memory
Input power
Peak-to-peak ripple
Detector start-up time
Normal current
consumption
Current consumption in
alarm
Maximum current
consumption
1.8 to 3.0 m (5.9 to
Mounting height
Target speed range
Alarm (NC) / Tamper relay
characteristic
Pry-off tamper
AM relay characteristic
Alarm time
Operating temperature
Dimensions (H x W x D)
Relative humidity
Weight
IP/IK rating
Regulatory information
Manufacturer
PLACED ON THE MARKET BY:
Carrier Fire & Security Americas Corporation Inc.
13995 Pasteur Blvd
Palm Beach Gardens, FL 33418, USA
AUTHORIZED EU REPRESENTATIVE:
Carrier Fire & Security B.V.
Kelvinstraat 7, 6003 DH Weert, Netherlands
Alarm
AM
To reset
relay
relay
Switch to Night
mode
Open
Do a successful
(Alarm)
walk test
Fast (4 Hz)
EV1012
EV1012AM
PIR
PIR + AM
DSP
12 m
9 high-density mirror curtains
No
Yes
9 to 15 V
(12 V nominal)
2 V (at 12 V )
25 s
60 s
4.4 mA
10 mA
1.2 mA
3.8 mA
11 mA
24 mA
2.0 to 3.0 m (6.6 to
9.8 ft.)
9.8 ft.)
30 cm/s to 3 m/s
20 cm/s to 3 m/s
(1 ft./s to 10 ft./s)
(8 in./s to 10 ft./s)
80 mA
80 mA
30 V , resistive
30 V
N/A
Onboard (yes)
80 mA at 30 V
3 s
−10 to +55°C (14 to 130°F)
108 × 60 × 46 mm (4.25 × 2.36 × 1.81 in.)
95% max. noncondensing
120 g (4.2 oz.)
128 g (4.5 oz.)
IP30 IK02
max.
5 / 40