9.5) MENU LINGUA (lingua)
Used to set the programmer's language on the display.
9.6) MENU AUTOSET (AUTOset) FIG.V
• Launch an autoset operation by going to the relevant menu.
• As soon as you press the OK button, the ".... .... .... " message is displayed and the control
unit commands the device to perform a full cycle (opening followed by closing), dur-
ing which the minimum torque value required to move the leaf is set automatically.
During this stage, it is important to avoid breaking the photocells' beams and not
to use the START and STOP commands or the display.
Once this operation is complete, the control unit will have automatically set the
optimum torque values. Check them and, where necessary, edit them as described
in the programming section.
WARNING!! Check that the force of impact measured at the points
provided for by standard EN 12445 is lower than the value laid down
by standard EN 12453.
Warning!! While the autoset function is running, the obstacle detection
function is not active. Consequently, the installer must monitor the
automated system's movements and keep people and property out of range
of the automated system.
9.7) MENU REGOLAZIONE FINECORSA FIG. U
The VENERE D control panel has an opening and closing limit switch adjustment
menu, which simplifies the installation procedure.
Proceed as follows:
•
Launch a limit switch adjustment operation by going to the relevant menu
on the VENERE D panel (Fig.B).
•
When the "CLOSE" message is displayed, move the door to the desired closed
position using the "UP" and "DOWN" buttons on the control unit, bearing in
mind that the "DOWN" button closes the door, while the "UP" button opens
the door. As soon as the door is in the desired closed position, press the "OK"
button to store the closed travel limit position.
•
When the "OPEN" message is displayed, move the door to the desired open
position using the "UP" and "DOWN" buttons on the control unit, bearing in
mind that the "DOWN" button closes the door, while the "UP" button opens
the door.
As soon as the door is in the desired open position, press the "OK" button to
store the open travel limit position.
•
Position the "runner stop" correctly up against the runner and secure in place
with the screws (fig.U rif.6 A-B).
NOTE: These operations must be performed in "deadman" mode at reduced
speed and without the safety devices operating.
TABLE "A" - PARAMETERS MENU - (PARA )
Parameter
min.
max.
1
180
TCA
CL. D IST.
7
100
SLOUD
PARTIAL
00,1
06,0
OPEN
1
99
OP. F ORCE
1
99
CLS. F ORCE
40
99
OP SPEED
40
99
CL SPEED
(*) In the European Union, apply standard EN 12453 for force limitations, and standard EN 12445 for measuring method.
(**) Impact forces can be reduced by using deformable edges.
INSTALLATION MANUAL
Default
Personal
Definition
Automatic clos-
40
ing time [s]
Slow-down
distance
7
[cm]
Partial opening
01,0
[m]
Leaf force
during opening
75
[%]
Leaf force
during closing
75
[%]
Opening speed
99
[%}
Closing speed
99
[%]
9.8) STATISTICS
Connect the UNIVERSAL HANDHELD programmer to the control unit, enter the
CONTROL UNIT/STATISTICS menu and run through the statistics parameters screen:
-
Software version of card microprocessor.
-
Number of cycles performed. If the motors are replaced, write down the
number of operations performed so far.
-
Number of cycles performed since last service. Automatically reset every time
self-diagnosis is run or parameters are written.
-
Date of last service. Must be updated manually via the relevant "Update service
date" menu
-
System description. Allows for 16 characters to be entered to identify the
system.
9.9)PASSWORD MENU (PASSWORD)
Used to set a password for the board's wireless programming via the U-link network.
With "PROTECTION LEVEL" logic set to 1,2,3,4, the password is required to access
the programming menus. After 10 consecutive failed attempts to log in, you will
need to wait 3 minutes before trying again. During this time, whenever an at-
tempt is made to log in, the display will read "BLOC". The default password is 1234.
10) REMOTE TRANSMITTER PROGRAMMING FIG. X
This mode does not require access to the control panel.
11)U-LINK OPTIONAL MODULES
Refer to the U-link instructions for the modules.
12) FUSE REPLACEMENT FIG. Y
13) ACCESSORIES FIG. Y1
SM1
External release device to be applied to the cremone bolt already fitted
to the overhead door (1).
SET/S External release device with retracting handle for sectional doors mea-
suring max 50mm (2).
ST
Automatic bolt release device for spring-operated overhead doors. Fitted
to the control arm, it automatically releases the side door bolts (3).
Waiting time before automatic closing.
Motor slow-down distance during opening and closing, expressed in cm
WARNING: Once the parameter has been edited, a complete uninterrupted
opening-closing cycle is required.
WARNING: when the display reads "SET", obstacle detection is not active.
Partial opening distance following activation of PED pedestrian command. Set the numerical value
of partial opening in the range 10 cm (00,1) to 6 m (06,0)
Force exerted by leaf during opening. This is the percentage of force delivered, beyond
the force stored during the autoset cycle (and subsequently updated), before an
obstacle alarm is generated.
The parameter is set automatically by the autoset function.
WARNING: It affects impact force directly: make sure that current safety
requirements are met with the set value (*). Install anti-crush safety
devices where necessary (**).
Force exerted by leaf during closing. This is the percentage of force delivered, beyond
the force stored during the autoset cycle (and subsequently updated), before an
obstacle alarm is generated.
The parameter is set automatically by the autoset function.
WARNING: It affects impact force directly: make sure that current safety
requirements are met with the set value (*). Install anti-crush safety
devices where necessary (**).
Percentage of maximum speed that can be reached by motor during opening.
WARNING: Once the parameter has been edited, a complete uninterrupted
opening-closing cycle is required. WARNING: when the display reads "SET",
obstacle detection is not active.
Percentage of maximum speed that can be reached by motor during closing.
WARNING: Once the parameter has been edited, a complete uninterrupted
opening-closing cycle is required. WARNING: when the display reads "SET",
obstacle detection is not active.
Description
BOTTICELLI 800 U -
15