7
CLIMATIC SENSOR
7.1 Learning a climatic sensor
1. Press and release the learning key on the control unit, the red LED lights up.
2. Press and release the key on the sensor, the control unit signals the correct memorization with two flashes of the red LED.
Once memorized the sensor, you can test the transmission by pressing the key on the sensor, the control unit shows the
reception of the broadcast with a rapid flashing of the yellow LED.
7.2 Checking the motor direction during in alarm
This procedure is necessary to verify correct wiring of the motor, so that the awning will be closed in case of alarm.
1. Temporarily disable the operation of the light sensor DIP 5 OFF
2. With a transmitter or cabled inputs move the awning at about halfway and stop it
3. On the sensor, adjust the trimmer to minimum wind (TEST) and rotate the blades of the sensor at a constant speed for few
seconds.
4. The control unit will show the alarm with the blinking of the red LED and will reclose the awining
If the awning moves in opening remove power to the control unit and swap the motor cables 14-15 and make again the test
above.
If the awning moves in closing, wait until it is completely closed, press and hold the learning key until the red LED start blinking
faster, release the button.
Set the desired speed of wind on the sensor with the trimmer and re-able the light sensors DIP 5 ON.
7.3 Deleting a climatic sensor
1. Press and release the learning key on the card, the red LED lights up.
2. Press and release the key on the sensor, the control unit shows the deletion with four long flashes of the red LED.
8
ADVANCED SETTINGS
8.1 Setting the partial open position (only with light sensor enabled)
You can set a desired position for automatic opening due to the light sensor, this procedure can only be done if the light sensor
is present and enabled (DIP 5 ON).
1. Close the awning
2. Upon reaching the closed position, press and hold the learning key on the control unit until the red LED flashes rapidly, release
the key
3. Press and hold the open key of a transmitter or (only with DIP 2 ON) a cabled input until the yellow LED flashes quickly, the
awning begins to open, release the button
4. To set the position it's sufficient to stop the awning (with a stop or a close input)
8.2 Temporary exclusion of the rain and light sensors
This mode is used to temporarily disable the light and rain sensors (the rain sensor can be temporarily disabled only if DIP switch
3 ON)
1. Move the awning to the desired position
2. With the awning still in motion press and hold for 5 seconds the stop key or the key of opposite movement or cabled inputs
3. The control unit shows the disabling of the sensors with 1 flash per second of the yellow LED
The rain sensor: if the DIP 3 ON is disabled for 2 hours. if DIP switch 3 OFF is never disabled.
The light sensor: is disabled for a full cycle of light (night-day, day-night).
To exit the disabling sensors it's sufficient to provide an open or close command and the control unit will return to automatic
mode.
18