8.3 Winter mode
This mode allows you to inhibit all the automatic movements of the control unit, which is useful during the winter.
1. Awning must not be in movement, it can be stopped at any position
2. Press and hold the close button for 5 seconds
3. The yellow LED indicates the entry of the winter mode with a blink every 2 seconds
4. Once the awning has reached the closure, it inhibit any automatism
To exit the winter mode, it's sufficient to provide an opening command and the control unit will return to the automatic mode
8.4 "Clock" function
The clock function cannot be used with dead man modality (DIP 2 OFF) nor with the light sensor connected (DIP 5 ON).
This mode allows you to open and close the awning at specific times using a timer (which maintains closed the wired contact
"open" for more than 4 minutes).
The awning will remain open until the contact is closed.
An alarm will close the awning.
Once the alarm stops, the awning is getting opened, regardless of the position of the DIP 1.
8.5 LED indicator
The control unit is equipped with 8 LEDs for indicating the status of the sensors, and handling operations
LED1
LED2
LED3 LED4
LED5
LED6 LED7 LED8
LED1 ON: light above the set threshold
LED2 ON: wind speed above the set threshold
LED3 ON: rain detected
LED 4 ON: snow detected (see 6.3)
LED5 ON: the control unit is using the internal memory
LED6 ON: clock function
LED7 ON: awning is closing
LED8 ON: awning is opening
19