Descargar Imprimir esta página

RIB MINI WIRELESS Manual Del Usuario página 16

Cuadro de control para toldos con gestión de los sensores wireless
Ocultar thumbs Ver también para MINI WIRELESS:

Publicidad

Idiomas disponibles

Idiomas disponibles

6
SETTINGS
6.1 Control unit behaviour
MINI WIRELESS control unit drives motors with internal limit switches with an admitted opening time of 7 minutes.
In case in which the awning is stopped for the intervention of a limit switch, the control unit remains on the state of opening
awning until the reaching of the 7 minutes.
In this interval of time 2 "CLOSE" commands will be necessary to bring the awning on closing (because it will be necessary to
pass for the STOP state).
At the same way, in case in which the awning would be opened and the control unit would find itself in the state of "STOP", an
order of closing would draw back the awning for a time determined by the intervention of the limit switches of the motor.
Despite the awning has been totally closed, the control unit will continue on the closing state until the reaching of the 7 minutes.
For this reason in this interval of time 2 "OPEN" commands will be necessary to bring the awning on opening (because it will be
necessary to pass for the STOP state).
In conclusion, it is necessary to keep in mind that the condition of open/close awning for the control unit do not always correspond
to the real condition of the open/close awning.
NOTA: in case that the control unit is on the closing position and, through the manual override, the awning is brought to the
opening position, an intervention of the sensors (wind, light, rain, snow) will not make close the awning as, the control
unit is still under the closing position.
6.2 Control unit behaviour with light sensor enabled
The control MINI WIRELESS, with the use of the light sensor, becomes fully automatic and opens and closes depending on the
light threshold set on sensor.
The light sensor has priority over user commands (transmitters and cabled inputs).
The sensor status light is visible through the green LED of the control unit:
• Off status: light below the set threshold (awning closed)
• Blinking: light above the set threshold (open awning)
The state of the control unit is visible through the yellow LED of the control unit:
• 1 flash per second: temporary exclusion of the sensors (see 8.2)
• 1 blink every 2 seconds: winter mode (see 8.3)
• Flashing quickly: learning of automatic opening position (see 8.1)
6.3 Control unit behaviour during alarm (wind, rain, snow, disconnection)
The presence of an alarm will immediately close the awning and block the operation of the transmitters and cabled inputs for 7
minutes after the finishing of the alarm.
A slow flashing red LED indicates to the user the alarm condition.
The detection of the snow (snow alarm) occurs in two different ways depending on the type of sensor:
• Sensor powered from the mains: presence of rain and temperature below 4 °C (sensor with heater)
• Sensor powered by photovoltaic panel: only temperature lower than 4 °C regardless of the presence of rain (sensor not
equipped with heater)
A rapid flashing of the red LED indicates a disconnection alarm of the sensors, the awning can be activated only by disabling all
sensors (DIP 5, 6, 7, 8 OFF); in this case, however, the awning will not be closed by the presence of wind, rain or snow alarm.
6.4 Control unit behaviour after power failure
The control unit after a power failure, returns to automatic operation, starting as from the position of the awning before the
blackout.
Data, settings, transmitters and sensors will remain memorized.