Table 9
PUMP SHIELD - (Not sold as kit one piece per code)
DF30
A = Aluminum
-
IN: ASK SAMOA
P = PP
855645
OUT: 855625
B = Conductive
PP
Table 14
WETTED PUMP BODY (Not sold a kit one piece per code)
A = Aluminum
B = Conductive PP
C = Acetal
D = Conductive Acetal
N = Electroless Nickel Plated Aluminum
P = PP
S = SS
W = PVDF
K = Conductive PVDF
The pump does not work
Cause
The discharge valve on the discharge side is not open.
No air supply.
The air supply pressure is low.
Air leaks in connecting elements.
The air pipes or ancillary equipment is clogged with mud.
The exhaust port (muffler) of the pump is clogged with mud.
The fluid pipe is clogged with mud.
Pump is clogged with mud.
The pump runs but no fluid comes out
Cause
The valve on the suction side is not open.
Too much suction or discharge height.
Fluid pipe discharge side (including the filter) is clogged with mud.
Pump is clogged with mud.
The ball and ball seat is worn or damaged.
The flow is decreasing
Cause
The air supply pressure is low.
The air line or peripheral equipment clogged with mud.
Valve discharge side drive will not open normally.
The air mixes with the fluid.
Cavitation occurs.
Vibrations.
Ice formation in the air exhaust.
The fluid line (including the filter) plugged with mud.
The exhaust port (muffler) of the pump is clogged with mud.
Pump is clogged with mud.
Leakage of fluid through the hollow exhaust (silencer)
Cause
The diaphragm is damaged.
Remove and inspect the pump and replace the diaphragm.
Irregular vibration
Cause
The elements of connection and the
support of the pump are loose.
The air supply pressure is too high.
The range and ball valve vibrates.
Powered air leak pressure of 3 to 8 bar
Cause
Wear directional valve.
Replace directional valve components.
SAMOA Industrial, S.A. · Pol. Ind. Porceyo, I-14 · Camino del Fontán, 831 · 33392 - Gijón - Spain · Tel.: +34 985 381 488 · www.samoaindustrial.com
Alphanumeric pumps repair kit codes
DF30T
DF50
DF50T
IN: 755109
755108
OUT: 755108
IN: 855626
855625
OUT: 855625
DF30
-
855661
-
855660
-
755400
-
855676
855677
Open the discharge valve on the discharge side.
Turn on the compressor and open the air valve and air regulator.
Check the compressor and the configuration of the air line.
Check the connection elements and the tightening of the screws.
Check and clean the air line.
Check and clean the exhaust port and muffler.
Check and clean the fluid line.
Remove, inspect and clean the pump body.
Open the valve on the suction side.
Confirm the configuration of the pipe and reduce the height of the same.
Check and clean the fluid line.
Dismantle the pump, check and clean.
Inspect and replace parts.
Check the compressor and the configuration of the air line.
Check and clean the air line.
Adjust the discharge valve discharge side.
Replenish fluid and check the configuration of the pipe on the suction side.
Adjust air supply pressure and discharge pressure and reduce the suction.
Adjust air supply pressure and discharge pressure. Reduce the flow of the inlet valve to adjust pressure and volume of fluid.
Remove ice from the air bypass valve and check and clean the air filter. Use a pipe in the exhaust air that the ice does
not form in the muffler.
Check and clean the fluid pipe and strainer.
Check and clean the exhaust port and muffler.
Remove, inspect and clean the pump body.
Recommended measure
Recommended measure
Review each element of connection and tighten
the screws.
Adjust air supply pressure.
Adjust air supply pressure and exhaust pressure.
Recommended measure
Table 13
DF100
UPPER: 755113
A = Aluminum
LOWER: 755114
S = SS
UPPER: 855637
LOWER: 855636
UPPER: 855624
LOWER: 855625
DF30T
DF50
-
755104
-
855649
-
855618
-
855628
-
ASK SAMOA
-
855607
-
755050
-
855692
-
855697
Troubleshooting
Recommended measure
Recommended measure
Recommended measure
Irregular noise
Cause
The air supply pressure is too high.
The pump is clogged with sludge particles
larger than the diameter allowed.
In fluid with air bubbles
Cause
Diaphragm damaged.
Suction hose loose or broken.
No start-up and is leaking air without cycles
Cause
Stiff air sensors.
Wear directional valve.
VALVE CAPS (Not sold a kit one piece per code)
DF30
DF50
-
855107
-
ASK SAMOA
DF50T
755105
-
855619
-
-
855608
-
-
-
Recommended measure
Adjust air supply pressure.
Remove, check and clean the pump body.
Recommended measure
Replace diaphragm.
Tighten or replace.
Recommended measure
Change air sensor.
Replace.