RESET
TWICE
ONLY
with. a. pressure. gauche. connected.
to.the.intake.(2.fig..8/a),.making.sure.
pressure. corresponds. to. the. value.
given.under.point.1.3.
2.6
HEATER UNIT
In. "AqUA 30 OF/BF". and. "AqUA 30
OF/BF INOX".models,.the.heater.unit.
comes. on. with. the. consensus. of. the.
burner,. after. a. delay. of. a. maximum.
of. 90. seconds. required. to. bring. fuel.
in.the.nozzle.holder.area.up.to.a.tem-
perature.of.65°C..
Once. this. temperature. has. been.
reached,. the. thermostat,. which.
is. located. above. the. preheater. (1.
74
12
bar
3
fig.. 14/b),. will. give. consensus. for.
the. burner. to. start.. The. heater. will.
remain.on.for.as.long.as.the.burner.
stays.on.and.go.off.when.the.burne.
goes.off.
NOTE: "AqUA 40 OF/BF" and "AqUA
40 OF/BF INOX" model have no heat-
er unit, as it is not required.
2.7
ELECTRICAL CONNECTION
The.boiler.is.supplied.with.an.electric.
cable.and.the.electric.power.supply.
to. the. boiler. must. be. 230V-50Hz.
single-phase. through. a. fused. main.
switch.
5
6
7
KEY
. 1. Gas-oil.pump
2
. 2. Pressure.gauche.intake
. 3. Pressure.adjustment.screw
1
The. stat. cable,. whose. installation.
is.compulsory.for.obtaining.a.better.
adjustment. of. the. room. tempera-
ture,. must. be. connected. as. shown.
in.fig..9-9/a.
NOTE:
Device must be connected to an
efficient earthing system.
SIME declines all responsibility
for injury or damage to persons
resulting from the failure to pro-
vide for proper earthing of the
appliance.
Always turn off the power supply
before doing any work on the elec-
trical panel.
2
1
Fig..8
Fig..8/a