SAFETY STAT
The. safety. stat. is. of. the. manually.
resetting. type. and. opens,. causing.
the.main.burner.to.turn.off.immedi-
ately,.whenever.the.temperature.of.
110°C. is. exceeded. in. the. boiler.. To.
restore. boiler. operation,. unscrew.
the. black. cap. and. reset. the. button.
(fig..22).
Should the appliance "lock out"
again, please approach the author-
ised technical staff.
BURNER RESTART
In. case. that. ignition. or. operation.
faults.occur,.the.main.burner."locks.
out". and. the. red. lamp. lights. up.
on. the. control. panel.. Press. the.
"RESET". button. to. restart. the. igni-
tion.conditions.until.the.flame.lights.
up.(fig..23)..
This. operation. can. be. repeated. 2-3.
times. at. maximum. and. in. case. of.
failure. contact. the. authorised. tech-
nical.staff.
RED.WARNING.LIGHT.ON
ATTENTION: Make sure that there
is fuel in the tank and that the taps
are open. After each fill up of the
tank it is advisable to interrupt the
operation of the burner for about
one hour.
TURNING OFF BOILER
It. is. sufficient. to. press. the. main.
switch.to.turn.off.the.boiler.(fig..18).
Close.both.the.gas-feed.pipe.tap.and.
the. water. tap. if. the. boiler. remains.
inoperative.for.a.long.period.
RESET
BUTTON
RESET
TWICE
ONLY
60
40
80
ϒ C
20
100
0
120
1
Fig..22
0
40
20
0
Fig..23
83
2
bar
3
4
60
80
ϒ C
100
120

Publicidad

loading

Este manual también es adecuado para:

Aqua 30 ofAqua 30 dfAqua 40 ofAqua 40 dfAqua 30 of inoxAqua 30 df inox ... Mostrar todo