Do not use the thermometer if it malfunctions or has been damaged in any matter.
When the ambient temperature of the thermometer changes too much, such as
moving the Thermometer from one place of lower temperature to another place of
higher temperature, Allow the thermometer to remain in a room for 30 minutes
where the temperature is between15℃to 40℃(59℉- 104℉).
Remove primary batteries if equipment is not likely to be used for long time.
This product is not waterproof, do not be immersed in water or other liquid; If
cleaning and disinfection, please follow the "Care and Storage" section requirements.
Do not touch the sensor of infrared detection with your �ingers.
If a cold compress on the forehead fever patients, or take other measures to cool
down the temperature data will low, should be avoided in this case to measure body
temperature.
If measure human forehead temperature , please select "body" mode; for measure
other objects, liquids, food and other temperature please select "surface" mode.
This product must be operated in a stable environment, if the ambient environment
was mutations, please should be note whether there is fog on the sensor, if any,
before using accordance with the "Care and Storage" section to removing the fog.
Do not near strong electrostatic �ield or strong magnetic �ields, thus avoiding the
impact on the accuracy of the measurement data.
Do not mix the old and new batteries to avoid damage to the product.
It may affect the accuracy of measurements when the forehead is covered by hair,
perspiration, cap or scarf.
The measuring result of this product is only for your reference. If you have any
doubt, please measure the temperature in other methods.
Description of Non Contact Infrared Body Thermometer
Device principle and introduction
The HeTaiDa Non contact infrared body thermometer are hand-held, reusable,
battery operated devices, which can measure human body temperature on forehead,
the skin temperature on one's forehead.
The operation principle is based on Infrared Sensor technology. The IR sensor can
output different signal when measuring different object temperature or in different
ambient temperature, and the ASIC can turn the signal from IR Sensor to a digital
value and display it on the LCD.
Description on Controls, Indicators, and Symbols
1
2
7
3
8
4
9
6
5
Imagen 1: HTD8813 Termómetro de infrarrojos corporal
1. IR sensor
8. Body mode
2. Liquid crystal display(LCD)
9. Data indicator
3. MODE button
10. Indicator of measurement result
4. On/Scan button
11. Low Battery indicator
5.Battery Cover
12. Voice on/off indicator
6. Plastic Shell
13. Fahrenheit/.Celsius
7. Surface mode
14.Memory number
15Memory indicator
15
13
14
10
11
12
The device should be kept out of the reach of children/pets. When not in use, store
the device in a dry room and protect it against extreme moisture, heat, lint, dust and
direct sunlight. Never place any heavy objects on the storage case.
Do not throw batteries into �ire.
Only use recommended batteries. Do not use rechargeable batteries.
This thermometer will irreplaceable the diagnostic in hospitals.
Do not fall, disassemble or modify the device.
Do not use this device if you think it is damaged or notice anything unusual.
This device comprises sensitive components and must be treated with caution.
Observe the storage and operating conditions described in the 'Technical
Speci�ications' section.
Not servicing/maintenance while the thermometer is in use.
When using, shall not touch battery and the patient simultaneously.
Do not use the device if it is damaged/ degraded/loosened in any way. The
continuous use of a damaged unit may cause injury, improper results, or serious
danger.
Based on the current science and technology, other potential allergic reactions are
unknown.
This equipment needs to be installed and put into service in accordance with the
information provided in the ACCOMPANYING DOCUMENTS.
1- Overview
Intended Use
The HeTaiDa Non Contact Infrared Body Thermometers are designed to be used for
intermittent measurement and monitoring of human body temperature by
consumers in the home setting and primary care setting as screening tool.
Thermometer Applications
Thermometer
Thermometer Style
Model Number
HTD8813
Non Contact Infrared Body Thermometers
Equipment Symbols
Warning
Non sterile packaging
Consult instructions for use
Operating Temperature
40
Operating Humidity
This device compiles with Part 15
of FCC(Federal Communications
Commission) Rules.
Manufacturer
Serial number
IP22: The �irst number 2: Protected against solid foreign objects of Ф 12.5 mm and
greater. The second number: Protected against vertically falling water drops when
enclosure
Adult
Pediatric
Ear Forehead Ear Forehead
Restriction of Hazardous Substances
Batch code
Compliance with WEEE Standard
DO NOT THROW AWAY
Intended for multiple use
Operating atmospheric pressure
Indicates this device is in compliance
with MDD 93/42/EEC. 0598 is the
Noti�ied Body Number