Guidance and manufacture's declaration – electromagnetic immunity
The Non Contact Infrared Body Thermometer is intended for use in the electromagnetic environment
speci�ied below. The customer or the user of the Non Contact Infrared Body Thermometer should assure that
it is used in such an environment.
Immunity test
IEC 60601 test level
Conducted RF
3 Vrms
IEC 61000-4-6
150 kHz to 80 MHz
Radiated RF
Professional healthcare
IEC 61000-4-3
environment: 3 V/m
Home healthcare
environment: 10 Vm
80 MHz to 2700 MHz
NOTE 1
At 80 MHz and 800 MHz, the higher frequency range applies.
NOTE 2
These guidelines may not apply in all situations. Electromagnetic propagation is affected by absorption
and re�lection from structures, objects and people.
a Field strengths from �ixed transmitters, such as base stations for radio (cellular/cordless) telephones and land
mobile radios, amateur radio, AM and FM radio broadcast and TV broadcast cannot be predicted theoretically with
accuracy. To assess the electromagnetic environment due to �ixed RF transmitters, an electromagnetic site survey
should be considered. If the measured �ield strength in the location in which the Non Contact Infrared Body
Thermometer is used exceeds the applicable RF compliance level above, the Non Contact Infrared Body
Thermometer should be observed to verify normal operation. If abnormal performance is observed, additional
measures may be necessary, such as re-orienting or relocating the Non Contact Infrared Body Thermometer.
b Over the frequency range 150 kHz to 80 MHz, �ield strengths should be less than 3V/m.
9-Body temperature
● Body temperature varies from person to person and �luctuates during the course
of the day. For this reason, it is suggested to know one's normal, healthy forehead
temperature to correctly determine the temperature.
● Body temperature runs approximately from 35.5℃ to 37.8℃(95.9°F-100°F). To
determine if one has a fever, compare the temperature detected with the person's
normal temperature. A rise over the reference body temperature of 1℃(1°F) or more
is generally indication of fever.
● Different measurement sites(rectal, axillary, oral, frontal, auricular) will give
different readings. Therefore it is wrong to compare the measurement taken from
different sites.
● Here below are typical temperatures for adults, based on different measurement
sites:
-Rectal: 36.6℃ to 38℃/97.9°F-100.4°F
-Axillary: 34.7℃ to 37.3℃/94.5°F-99.1°F
ASTM laboratory accuracy requirements in the display range of 37℃(98°F to
102°F) for IR thermometers is ±0.2℃(±0.4°F), whereas for mercury in-glass and
electronic thermometers, the requirement per ASTM Standards E667-86 and
E1112-86 is ±0.1℃(±0.2°F).
Caution: This infrared thermometer meets requirements established in ASTM
Standard (E1965-98) Except of clause 5.2.2. It displays subject's temperature over a
range of 34.0~43.0℃. Full responsibility for the conformance of this product to the
standard is assumed by(Hetaida Technology Co., Ltd. Add: Room 801, 802, 803, 804,
901, 2# Building Scienti�ic Research Center, Songhu Intelligent Valley, No.6 Minfu
Road, Liaobu Town, Dongguan City, Guangdong Province, P.R.China
Compliance level
Not applicable
Same as the left.
Guidance and manufacturer's declaration
-
RF wireless communication equipment immunity
Test
a)
a)
Band
Service
Modulation
frequency
(MHz)
(MHz)
Pulse
modulation
385
380 - 390
TETRA 400
18 Hz
FM
GMRS 460,
±
5 kHz deviation
450
430
-
470
FRS 460
1 kHz sine
710
Pulse
LTE Band
13,
modulation
745
704 - 787
17
217 Hz
780
810
GSM 800/900,
Pulse
TETRA
800,
modulation
870
800 - 960
iDEN 820,
CDMA 850,
18 Hz
930
LTE Band 5
1720
GSM 1800;
CDMA 1900;
Pulse
1845
1700 -
GSM 1900;
modulation
1990
DECT;
217 Hz
LTE Band
1,
3,
1970
4, 25; UMTS
Bluetooth,
Pulse
WLAN,
2400 -
modulation
2450
802.11 b/g/n,
2570
RFID 2450,
217 Hz
LTE Band 7
5240
Pulse
5100
-
WLAN 802.11
modulation
5500
5800
a/n
217 Hz
5785
a)
For some
services,
only
the
uplink frequencies are
included.
b)
The carrier shall be modulated using a 50 % duty cycle square wave signal.
c)
As an alternative to FM modulation, 50 % pulse modulation at 18 Hz may be used because while it does not
represent actual modulation, it would be worst case.
Maximum
IMMUNITY
b)
Distance
power
TEST LEVEL
(m)
(V/m)
(W)
b)
1,8
0,3
27
c)
2
0,3
28
b)
0,2
0,3
9
b)
2
0,3
28
b)
2
0,3
28
b)
2
0,3
28
b)
0,2
0,3
9