CARE AND MAINTENANCE
Maintenance parts can be purchased directly from the factory. A partial list of maintenance parts is below. For a
complete list of maintenance parts or for additional information email us at
1-855-944-3571
call
Air Filter (Upper) ....................................................................................................................................810703171
Air Filter (Lower) ....................................................................................................................................810703169
Exhaust Hose ........................................................................................................................................810703229
Hose Inlet ............................................................................................................................................810701997A
Hose Outlet............................................................................................................................................810702769
Remote Control .................................................................................................................................. 810900800K
Window Vent Kit (Sliding Panel and Fixed Panel) .................................................................................810702837
Upper Drain Plug Cap .........................................................................................................................810701299A
Lower Drain Plug Cap ................................................................................................... 810701900 / 810701898B
Drain Hose...........................................................................................................................................810700928F
Casters .................................................................................................................................................. 810701160
WARNING
product. Making unauthorized modifications and using incompatible accessories can damage the unit and
void your warranty.
TROUBLESHOOTING
PROBLEM
The air conditioner
does not start
Runs for a short time
then stops
The air conditioner
starts but doesn't cool
The unit will not run
and "ft" appears on the
display
20 | English
.
Do not use attachments or accessories that are not recommended for use with this
POSSIBLE CAUSE
No electricity
Batteries in remote control need to be
replaced
The power cord is not plugged in properly
The LCDI on the power cord has tripped
The temperature setting is too close to the
room temperature
The air outlet is blocked
The exhaust hose has sharp bends or sags
A door or window is open
The filters are dirty
The exhaust hose is not connected
The temperature setting is too high
The air oulet or air intake is blocked
The room exceeds the recommended size
Direct sunlight decreasing cooling effect
Excess water condensation is inside the
tank.
service@wpowereq.com
CORRECTION
Check power source
Replace batteries
Remove and reconnect power cord
Reset the LCDI
Lower the temperature setting
Remove the blockage
Straighten the hose
Close doors and windows
Clean the filters
Attach the exhaust hose
Lower the temperature setting
Remove blockage
Move the unit to a smaller room
Cover windows with curtains or blinds
Drain the tank.