ESPAÑOL, página 110
-
-
-
-
-
Troubleshooting
Problem
2. Product does
not reach full
power
3. No water jet
4. Strong
pressure
5. Water leakage
from product
6. Excessive
vibration/noise
Possible cause
2.1
Extension cord
not suitable for
operation with this
product
2.2
Power source (e.g.
generator) has a too
low voltage
2.3
Air vents are
blocked
supply
2.5
Filter is dirty
2.6
Hose partly blocked
2.7
Nozzle partly
blocked
3.1
Trigger is not
pressed
3.2
Trigger lock is
activated
3.3
No water supply
3.4
Filter is dirty
2.5
Hose blocked
3.6
Nozzle blocked
4.1
Nozzle is blocked
4.2
Water inlet volume is
too low
4.3
Pressure hose is
leaking
5.1
Small leakage in the
product related to its
technical conditions
are not a problem
6.1
Screw and nuts
loosened
6.2
Motor problems
FPHPC100
Solution
2.1
Use a suitable
extension cord
2.2
Connect to another
power source
2.3
Clean the air vents
2.4
Check water supply
2.6
Check hose
2.7
Check nozzle(1a)
3.1
Press the
trigger(2c)
3.2
Deactivate the
trigger lock(2c)
3.3
Check water supply
3.5
Check hose
3.6
Check nozzle(1a)
4.1
Clean the
nozzle(1a)
4.2
Increase water inlet
quantity
4.3
Replace pressure
hose(3)
5.1
Have electrician
examine in case of
strong leakage
6.1
Check screws and
nuts for tightness
and re-tighten as
necessary
6.2
Have the product
examined by
GB