EN
Set auto comfort
12:12
20.0°C
Set auto reduced
12:12
18.0°C
Boiler Time Schedule
12:12
Day:
Monday
[1] 07:30 - 08:30
[3] 18:00 - 22:30
[2] 12:00 - 13:30
[4]
Curve Slope
12:12
1.0
desired
Set auto comfort:
room temperature in AUTO
during the comfort
mode
periods.
desired
Set auto reduced:
room temperature in AUTO
mode
outside the comfort
periods.
the boiler is config-
Curve slope:
ured for connecting to an exter-
nal air temperature sensor and
can operate with a sliding tem-
perature. The boiler's delivery
temperature varies in relation
to the external temperature de-
pending on the selected climat-
ic curve. ( refer to the "CLIMATIC
graph).
CURVE SLOPE"
Room
influence:
Ambient inf.
12:12
boiler's delivery tem-
perature can also be
50%
influenced by the tem-
perature measured in
the room depending on
the set weight ( 0% = no
influence
the boiler's de-
K Amb:
K Amb
12:12
livery temperature can
also be influenced by the
4.0
temperature measured
in the room depending
on the slope character-
ising the selected room
component. (refer to the
"ROOM
SLOPE" graph).
Offset Z1:
Offset Z1
12:12
increase or reduce the
boiler's delivery temper-
0°C
ature by a constant value
compared to the auto-
matic adjustment with a
selected climatic curve
and room component.
the
).
COMPENSATION
It is possible to
35