1.5 Cooling liquid
1.5.1 Personal protection
Product harmful if swallowed. Can cause irritation
to eyes, mucous membranes and skin.
Use rubber gloves to prevent contact.
Use safety goggles to prevent accidental splashes.
Wear ordinary work clothes to prevent contact with
the skin.
1.5.2 Disposal
Any leaks or remains of product, after it has been
used, must be treated in a suitable purification plant
or recycled if possible. Do not discharge the used
product into watercourses, ditches or drainage sys-
tems. The diluted fluid should not be discharged into
the sewers unless permitted by the local regulations.
2 INSTALLATION
Installation should be performed only by expert
personnel authorised by the manufacturer.
During installation, ensure that the power source is
disconnected from the mains.
2.1 Lifting, transport and unloading
procedures
- The system is not equipped with specific lifting gear.
Do not underestimate the weight of the equip-
ment: see technical specifications.
Do not move or position the suspended load
above persons or things.
Do not drop or apply undue pressure on the
equipment.
12
2.2 Positioning of the equipment
Keep to the following rules:
- Provide easy access to the equipment controls and connec-
tions.
- Do not position the equipment in very small spaces.
- Do not place the equipment on surfaces with inclination
exceeding 10° from to the horizontal plane.
- Position the equipment in a dry, clean and suitably ventilated
place.
- Protect the equipment against pouring rain and sun.
2.3 Connection
The cooling unit is provided with a connector J1 for connection
to the power source.
Disconnect the power supply before every opera-
tion!
- Remove the left side cover of the power source.
Connect the wire leads of the cooling unit to the appropriate
connector.
- Insert the wire lead numbered 78 in the terminal numbered
78 and tighten the screw.
- Insert the wire lead numbered 0 in the terminal numbered 0
and tighten the screw.
- Insert the yellow-green earth wire lead in the terminal marked
PE and tighten the screw.
- Insert the wire lead numbered 10 into the terminal numbered
10 and tighten the screw.
- Insert the wire lead numbered 00 into the terminal numbered
00 and tighten the screw.
- Tighten the cable clamp in order to secure the cable on the
rear of the machine.
- Close the side cover of the power source.