3. Specifications
3. Specifications
Temperature ranges
Medium temperature (measuring range)
■
The measuring range basically depends on the insulation material of the connecting
cable and on the measuring element:
Insulation material of the connecting cable
PVC
Silicone
PTFE
Measuring element
NTC
Pt100
Pt1000
Ni1000
KTY
Ambient temperature
■
The max. permissible ambient temperature depends on the insulation material of the
connecting cable.
Storage temperature
■
-40 ... +85 °C
Protect the gauges from humidity and dust!
Vibration resistance
Depending on the medium, temperature and immersion depth vibration resistance averages
according to DIN EN 60751 up to 6 g.
Shock resistance
up to 100 g, depending on the mounting position, medium and temperature
Electrical connection
Blank connecting wires
■
End splices
■
Connector to specification
■
Ingress protection
IP 65
For further specifications see WIKA data sheet TE 67.15 and the order documentation.
WIKA operating instructions insertion thermometer, model TF45
Measuring range
-30 ... +130 °C
-50 ... +400 °C
-50 ... +400 °C
-50 ... +250 °C
-50 ... +150 °C
Measuring range
-20 ... +105 °C
-50 ... +200 °C
-50 ... +260 °C
GB
7