Specifications; Measuring Range - WIKA TF45 Manual De Instrucciones

Ocultar thumbs Ver también para TF45:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

3. Specifications

3. Specifications
Temperature ranges
Medium temperature (measuring range)
The measuring range basically depends on the insulation material of the connecting
cable and on the measuring element:
Insulation material of the connecting cable
PVC
Silicone
PTFE
Measuring element
NTC
Pt100
Pt1000
Ni1000
KTY
Ambient temperature
The max. permissible ambient temperature depends on the insulation material of the
connecting cable.
Storage temperature
-40 ... +85 °C
Protect the gauges from humidity and dust!
Vibration resistance
Depending on the medium, temperature and immersion depth vibration resistance averages
according to DIN EN 60751 up to 6 g.
Shock resistance
up to 100 g, depending on the mounting position, medium and temperature
Electrical connection
Blank connecting wires
End splices
Connector to specification
Ingress protection
IP 65
For further specifications see WIKA data sheet TE 67.15 and the order documentation.
WIKA operating instructions insertion thermometer, model TF45

Measuring range

-30 ... +130 °C
-50 ... +400 °C
-50 ... +400 °C
-50 ... +250 °C
-50 ... +150 °C
Measuring range
-20 ... +105 °C
-50 ... +200 °C
-50 ... +260 °C
GB
7

Publicidad

Tabla de contenido
loading