Descargar Imprimir esta página

STAR Water Systems STPP15VS Manual De Instrucciones página 14

Publicidad

Idiomas disponibles

Idiomas disponibles

MAINTENANCE
DO NOT run the pump dry. If the pump is run dry, the mechanical seal will be damaged and the
pump will start leaking. If this occurs, the damaged seal must be replaced. ALWAYS maintain
proper water level. If the water level falls below the suction port, the pump will draw air through the suction port, losing
the prime and causing the pump to run dry, resulting in a damaged seal. Continued operation in this manner could cause
a loss of pressure, resulting in damage to the pump case, impeller and seal, and may cause property damage and
personal injury.
Pump Reassembly
1. When installing the replacement seal into the seal
plate, use soapy water to wet the rubber boot
before pressing it into the seal plate.
2. Remount the seal plate to the motor mounting
plate.
3. Before installing the rotating part of the seal on the
impeller shaft, wet the impeller shaft with soapy
water and slide the seal to the impeller shaft end.
Remove the dirt from the contact surface of the
seal with a clean cloth.
4. Screw impeller onto the motor shaft (clockwise to
tighten).
Note: Insert a Phillips screwdriver into the hole of the
motor fan.
5. Remount the diffuser onto the seal plate.
6. Grease the diffuser quad ring and seal plate o-ring
prior to reassembly.
7. Assemble the motor sub-assembly to the strainer
pot-pump body. Tighten the bolts until all 4 bolts
are in place and ginger tightened.
8. Fill the pump with water.
9. Reinstall the pump lid and plastic clamp. See the
next section, 'Restart Instructions'.
10. Re-prime the system
14
Copyright © 2022. All rights reserved • 95 North Oak Street • Kendallville, IN 46755
Restart Instructions
If Variable Speed Pump is installed below the water
level of the pool, close return and suction lines prior
to opening hair and lint pot on pump. Make sure to re-
open valves prior to operating.
Priming the Pump
The pump strainer pot must be filled with water before
the pump is initially started.
Follow these steps to prime the pump:
1. Remove the pump lid plastic clamp. Remove the
pump lid.
2. Fill the pump strainer pot with water.
3. Reassemble the pump cover and plastic clamp
onto the strainer pot. The pump is now ready to
prime.
4. Open the air release valve on the filter, and stand
clear of the filter.
5. Turn on the power to the pump.
6. Press the Start/Stop button on the drive keypad.
If the pump is currently scheduled to run, it will
start.
Note: If the pump is not scheduled to start, press a
SPEED button to begin a manual override that will
start the pump.
7. When water comes out of the air release valve,
close the valve. The system should now be free of
air and recirculating water to and from the pool.

Publicidad