EN
DE
•
Keep the spray gun at right angles to the surface. This means moving your entire arm back and forth rather than just flexing your
wrist. (Fig. 17, B)
•
Keep the spray gun perpendicular to the surface, otherwise one end of the pattern will be thicker than the other. (Fig. 17, C)
•
Trigger gun after starting the stroke. Release the trigger before ending the stroke. (Fig. 17, D) The spray gun should be moving when the
trigger is pulled and released. Overlap each stroke by about 30%. This will ensure an even coating.
During operation the pump switches on and off continuously, in order to regulate the pressure.
i
This is normal and is not a malfunction.
Unclogging the Spray nozzle
If the spray pattern becomes distorted or stops completely while the gun is triggered, follow these steps.
Do not attempt to unclog or clean the nozzle with your finger. High pressure fluid can cause injection injury.
Danger
1. 1. Release the trigger and secure the gun. Rotate the reversible nozzle arrow 180º so that the point of the arrow is toward the
Release the trigger and secure the gun. Rotate the reversible nozzle arrow 180º so that the point of the arrow is toward the
rear of the gun.
rear of the gun. (Fig. 18).
Under pressure, the nozzle may be very difficult to turn. Turn the switch to the PRIME position (vertical) and pull the
i
trigger. This will relieve pressure and the tip will turn more easily.
2. Turn the switch to the SPRAY position (horizontal).
3. Unlock the gun and squeeze the trigger, pointing the gun at a scrap piece of wood or cardboard. This allows pressure in the spray
hose to blow out the obstruction. When the nozzle is clean, material will come out in a straight, high pressure stream.
4. Release the trigger and secure the gun.
Release the trigger and secure the gun. Reverse the nozzle so the arrow points forward again. Unlock the gun and resume
spraying.
i
The HEA Filter Set keeps nozzle blockages to a minimum (see "HEA Filter Set").
HEA Filter Set
Assembly
The gun and high-pressure hose must be de-pressurised before
the filter set is installed / removed.
Danger
1. 1. Disconnect the high-pressure hose from the gun (1).
Disconnect the high-pressure hose from the gun (1).
2. 2. If necessary, screw on the filter housing (2) and insert a filter (3) appropriate
If necessary, screw on the filter housing (2) and insert a filter (3) appropriate
to the nozzle (the conical side (A) must point upwards).
to the nozzle (the conical side (A) must point upwards).
Nozzle 311
Filter red
Nozzle 517 / 619 Filter white (pre-installed in the filter housing)
3. 3. Screw the filter housing (2) to the gun (1).
Screw the filter housing (2) to the gun (1).
4. 4. Screw the high-pressure hose (4) firmly to the filter housing (2).
Screw the high-pressure hose (4) firmly to the filter housing (2).
Cleaning
The gun and high-pressure hose must be de-pressurised before
the filter set is installed / removed.
Danger
1. 1. Remove the filter housing (2) from the hose (4) and the gun (1).
Remove the filter housing (2) from the hose (4) and the gun (1).
2. 2. Screw on the filter housing (2) and remove the filter (3).
Screw on the filter housing (2) and remove the filter (3).
3. 3. Thoroughly clean the filter (3) and filter housing (2) (if worn, replace the filter).
Thoroughly clean the filter (3) and filter housing (2) (if worn, replace the filter).
4. 4. During reassembly, take care not to lose the seal (5).
During reassembly, take care not to lose the seal (5).
24
Control Pro 250 M / 275 M
2
4
1
A
5
3