Replace or turn vacuum lips
 Dismantle the vacuum bar.
1 Lock nut
 Unscrew the knurled nuts.
 Remove the suction bar insert from the
bottom of the suction bar.
1 Vacuum lip
2 Suction bar insert
 Remove the vacuum lips from the suc-
tion bar insert.
Note:
The vacuum lip can be turned around 3
times until all edges are worn. Then a new
vacuum lip is required.
A blinking battery display indicates the following faults. The time sequence of the blinking segments indicates the type of fault.
Number of flashes Fault
1
Battery discharged oder battery cable damaged.
2
Cable to drive motor interrupted.
3
Cable to drive motor shorted.
4
Deep discharge power not reached
5
--
6
Drive attempt while charger is connected (Bp Pack
model only).
7
Fault in drive pedal.
8
Control faulty.
9
Parking brake fault.
10
Shorted connection on battery connection.
Once every 5 sec-
Control idle.
onds
Blinking signal
Fault
Blinks red
Battery poled or is not connected
Blinks green and yel-
Cable connection between battery and charger is
low.
poor.
Battery defective
 Before restarting the charger, pull the plug out of the socket, wait until the charge status indicator shuts off and plug the mains plug
back in.
 Reverse the suction lip or replace it and
rehook it into the hooks of the suction
bar insert.
 Place the suction bar insert into the suc-
tion bar.
 Screw on the knurled nuts and tighten
them.
Replacing the disk brushes
 Lift the cleaning head.
 Turn key to "0" and remove it.
 Turn the unlocking lever of the sliding
brush in an anti-clockwise direction -
the brushes will fall downward and can
be pulled outward at the bottom of the
device.
 Hold the new brush under the cleaning
head.
 Turn the unlocking lever of the sliding
brush in clockwise direction and press
the brush upward.
 Release the unlocking lever and check
that the brush is sitting properly.
Maintenance tasks - all types
Cleaning the floater
1 Sieve with floater ball
2 Pipe
Errors shown by the battery indicator
Errors shown by the charge status indicator (only Bp Pack model)
Remedy
Check battery cable, charge battery.
Inform Customer Service.
Charge battery.
--
Remove the power plug from the charger and hook the hold-
er into the appliance (model Bp Pack only).
Release the drive pedal prior to turning on the appliance.
Inform Customer Service.
Check the terminals on the batteries.
Turn the main switch to "0" and turn it back to "1".
Remedy
Check battery cable for correct sitting.
Check battery cable for correct sitting.
Check whether the connection to the battery was interrupted
during the charge process.
Check battery.
7
-
EN
 Clean the sieve from the outside and
rinse it.
 Check the mobility of the floater ball.
If it is too dirty:
 Hold the pipe firmly and pull out the
sieve from the pipe.
 Clean sieve and ball.
 Hold the pipe firmly and reinsert the
sieve.
Frost protection
In case of danger of frost:
 Empty the fresh and waste water tank.
 Store the appliance in a frost-protected
room.
Faults
DANGER
Risk of injury! Before carrying out any tasks
on the machine, set the main key to "0" and
remove it. Pull the battery plug.
WARNING
Suction turbine will continue to run for a
while after switch-off. Carry out mainte-
nance tasks only after the suction turbine
has come to a halt.
In case of faults that cannot be remedied
using the table below please contact the
customer service.