Descargar Imprimir esta página

Starmix AirStar T-C1 M Instrucciones Para El Manejo página 21

Ocultar thumbs Ver también para AirStar T-C1 M:

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 33
Safety features
The hand dryer is equipped with the following safety features:
– Safety cut-o昀昀 sensor a昀琀er 35 seconds
– Safety temperature limiter in case of overhea琀椀ng, e.g. if outlet opening is blocked
– Thermal fuse in case of overhea琀椀ng
The hair dryer is equipped with the following safety features:
– Safety cut-o昀昀 sensor a昀琀er approx. 4 minutes, e.g. in case of chewing gum vandalism
– Safety temperature limiter in case of overhea琀椀ng, e.g. if outlet opening is blocked
– Thermal fuse in case of overhea琀椀ng
5 Conduct in case of emergency
In cases of 昀椀re hazard, electrical shock, mechanical damage, unusual opera琀椀ng condi琀椀ons or misuse, proceed as
follows:
1. Unplug power cord. With 昀椀xed connec琀椀on: Switch o昀昀 circuit breaker or unscrew fuse.
2. Secure against accidental switching on.
6 Troubleshoo琀椀ng and repairs
Malfunc琀椀on
The device does not start
Air output is insu昀케cient
Do not take any further ac琀椀on; contact customer service instead.
7 Maintenance
Clean the air intake grille
See Fig. I
Clean the air intake grille at regular intervals, but at least every 6 months. The air intake grille may only be
cleaned by trained specialist personnel.
Cause
Sensor is soiled
Fuse has tripped
Overhea琀椀ng due to blocked outlet
opening
The thermal fuse was triggered
Air intake grille is soiled
Remedy
Remove dirt from sensor and wipe
with damp cloth
Switch on circuit breaker or
replace fuse
Clean out outlet opening, allow
device to cool down
Have thermal fuse replaced by
customer service
Clean air intake grille
en
21

Publicidad

loading

Este manual también es adecuado para:

Airstar t-c1 mwAirstar th-c1 mAirstar th-c1 mw