Descargar Imprimir esta página

Mennekes AMTRON Compact 2.0s 7,4 Manual De Instrucciones Y De Instalación página 67

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 81
6.2.3.2
Connection and configuration
Connecting an external energy meter
The product is compatible with the following energy
meters:
n Siemens PAC1600 7KT1661 (The energy meter
incl. the current transformer and instructions
can be ordered from MENNEKES using part no.
18626.)
n TQ Energy Manager EM 420 / KOSTAL Smart
Energy Meter
u Install the external energy meter in the up-
stream electrical installation.
u Connect the energy meter and the product with
a data cable.
1 "5.7 Connecting the data line (Modbus RTU)"
[} 16]
Configuration
For solar charging, the following settings have to be
made using DIP switches:
DIP switch
Required
(bank S1)
configura-
tion
4
ON
5
OFF
6
Depend-
ent on en-
ergy meter
7
ON
Configuration tool:
If the energy meter is to measure external con-
sumers only, an additional setting has to be made
in the configuration tool ("Meter measuring point"
parameter).
1 "6.5.1 Description of the configuration tool"
[} 28]
Brief description
Using Modbus RTU
Master
n "OFF" = Siemens
PAC1600 7KT1661
n "ON" = TQ Energy
Manager EM 420 /
KOSTAL Smart En-
ergy Meter
Solar charging activated
Blackout protection:
Blackout protection is enabled automatically for
solar charging, which is why the max. amperage
provided by the building connection must also be
set via the DIP switches.
1 "6.2.2 Blackout protection" [} 20]
Selecting the charging mode
2
Fig. 14: Sun button
Press the Sun button (1) to select the charging
mode according to the following diagram.
Standard
Mode
Fig. 15: Switching the charging modes
The set charging mode is indicated by the "Sun" (2)
LED:
Status of "Sun" LED
Off (is not lit)
Lights up
Pulsates
n The Sun button has no function unless
solar charging has been set up.
n Switching from Standard mode, Sunshine
mode or Sunshine+ mode is always pos-
sible (also while charging is in progress).
1
Sunshine
Sunshine+
Mode
Mode
Set charging mode
Standard mode
Sunshine mode
Sunshine+ mode
EN
25

Publicidad

loading