Uline H-4012 Manual Del Usuario página 2

Selladoraal vacío - 20

Publicidad

Idiomas disponibles

Idiomas disponibles

NOTE: See references on page 3.
MAIN POWER SWITCH – Turns power off and on.
FOOT SWITCH – Controls vacuum cycle and initiates
seal cycle.
HEAT TIMER – Controls heating time. To increase heat,
turn heat timer knob clockwise. To decrease, turn knob
counterclockwise. Timer is set in seconds – 10 seconds
maximum.
COOL TIMER – Controls amount of time that pressure
bar remains closed for cooling. To increase cool time,
turn cool timer knob clockwise. To decrease, turn knob
counterclockwise. Timer is calibrated in increments of
1/10 minute.
SETUP
1.
Place the sealer on a flat working surface.
2. Locate the "Air In" port on rear.
3. Attach clean, dry air supply using
tubing (supplied with sealer).
4. Verify air pressure.
CAUTION! Do not exceed 85 psi.
START-UP
WARNING! Keep fingers away from seal jaw.
1.
Insert plug into 120VAC, 60Hz outlet.
2. Turn sealer ON by pressing main power switch.
3. Set heat timer at #2 position (2 seconds) and cool
timer at #1 (6 seconds).
OPERATION
IMPORTANT! If you are vacuuming a granular or
fine substance, the machine will need a filter.
Failure to use a filter will clog the ejector and
the machine will not be able to vacuum.
1.
Load the product into the bag and place the bag
opening over the nozzle (between the sealing jaws).
Pull the bag so its seal area is straight and crease-
free.
PAGE 2 OF 17
CONTROLS
OPERATION
/
" OD plastic
1
4
LED INDICATORS ON HEAT/COOL TIMERS:
• UNLIT: Timer is not active.
• SOLID COLOR: Timer is active.
• FLASHING: Timer has timed-out.
2. Press foot switch. Jaws will close and heat timer LED
will illuminate.
3. Remove bag and inspect seal. If the seal is weak,
increase heat timer slightly. Adjust cool timer to
allow plastic to cool before pressure bar reopens.
4. Hold foot switch until desired vacuum level is
achieved. Sealing cycle will initiate when Foot
Switch is released.
5. The sealing jaws will automatically release when
heating and cooling cycles are completed. The
machine will then return to its pre-set heating and
cooling cycles.
6. Continuously monitor seal area. If the area
overheats, lower heating time and increase
cooling time.
7. At the end of each shift or production run, turn sealer
OFF by pressing the main power switch.
NOTE: Sealing cycle may be aborted at any
time by turning main power switch to "OFF."
HEATING TIPS
• Uline recommends cooling time should be double
the heating time.
• To extend element life and avoid overheating, set
heat timer at the lowest number for the required seal.
Slight adjustments can significantly change results.