OPERATING ISSUE
No/Poor Vacuum
No Heat/Poor or Weak
Seal
No Heat
No Cool
Bag Sticks to Seal Jaw
Gaps/Creases in Seal
Nozzle does not
retract or extends too
slow/fast
The Pressure Bar does
not close. One side
sticks open.
Premature element
burn out. Element is
sparking.
Jaws do not close
PAGE 5 OF 17
TROUBLESHOOTING CONTINUED
ACTIONS
Check incoming air pressure.
Check bag.
Increase heat time settings.
Check element for hot spots or
burn through. Element should
be extended all the way to the
right.
Check element finger nuts.
Check contact surfaces.
Check fuse.
Check bag.
Check the Pressure Bar.
Check bag.
Check element and Teflon
for bumps, hot spots, burns or
creases.
Check incoming air pressure.
Adjust Nozzle Extend Flow
Control.
Realign Pressure Bar pistons.
Check procedure for proper
element replacement.
Check incoming air pressure.
1-800-295-5510
Air pressure should be set to 75-85 psi.
Make sure bag is flat and crease-free between
vac seal jaws. Use both hands to support bag.
Note: Optional support tray may help when
vacuuming larger/bulkier packages.
Replace element. Turn the sealer on again.
Ensure they are tight with no gaps.
Ensure all contact surfaces are clean.
If burnt out, replace fuse.
Increase cool time.
Replace if necessary.
Ensure bag is flat when vac jaw closes.
Increase heat and cool times. Replace element
®
and Teflon
as necessary.
®
Air pressure should be set at 75-85 psi.
Reduce/increase opening in Nozzle Extend Flow
Control to slow down/speed up nozzle extend.
To realign, disconnect air pressure, close jaw by
hand, loosen and retighten Pressure Bar piston
nuts.
Confirm flaps are facing up. Make sure nuts are
tight and there are no gaps.
Air pressure should be set to 75-85 psi.
uline.com
RECOMMENDATIONS
0123 IH-4012