Operating Instructions
Maintenance (Continued)
can be made to a bent gun body. Test
the needle by rolling on a flat surface.
Replace if necessary.
4. Check and replace any damaged
o-rings and seals. o-rings and seals
can be wiped clean but not soaked
in solvent.
5. Unscrew packing nuts and replace
the packing ONLY if a leak will not
stop when the nut is tightened.
Do not over-tighten a packing nut
because this will restrict movement
of the needle.
6. Reassemble in reverse order of these
steps and use a non-silicone oil on
moving parts. Apply Vaseline
light grease on threaded joints and
hose connections.
Notes
www.campbellhausfeld.com
STORING
1. When not using spray gun, turn the
fluid control knob counterclockwise
to open reducing spring tension on
needle fluid tip.
2. Spray gun MUST BE well cleaned and
lightly lubricated.
or
®