Range
600mV
6V
60V
600V
700V
1
Frequency Range for ACV: 40Hz~400Hz
2
Response for ACV: avg, calibrated in RMS of sine wave
Overload protection: 1,000VDC or 700VAC RMS
Input impedance (nominal): > 10MΩ; AC voltage: > 10MΩ
Common mode rejection ratio: DC voltage: > 100dB @ DC, 50 or 60Hz; AC voltage: > 60dB @ DC, 50 or 60Hz
Normal mode rejection ratio: DC voltage: > 45dB @ 50 or 60Hz
Frequency
Range
99.99Hz
999.9Hz
9.999kHz
99.99kHz
999.9kHz
Overload protection: 250VDC or 250VAC RMS
Resistance
Range
600.0Ω
6.000kΩ
60.00kΩ
600.0kΩ
6.000MΩ
60.00MΩ
Overload protection: 250VDC or 250VAC RMS
Diode Test
Range
1V
Forward DC Current: ± 1mA
Reverse DC Voltage: ± 1.5V
Overload Protection: 250VDC or 250VAC RMS
Continuity Check
Range
600Ω
Continuity beeper: ≤ 50Ω
Overload Protection: 250VDC or 250VAC RMS
DVM1200
AC Voltage
Resolution
0.1mV
1mV
10mV
100mV
1V
Resolution
0.01Hz
0.1Hz
0.001kHz
0.01kHz
0.1kHz
Resolution
0.1Ω
1Ω
10Ω
100Ω
1kΩ
10kΩ
Resolution
0.001V
Resolution
0.1Ω
- 11 -
Accuracy
± (3.0% of rdg ± 3 digits) (manual)
± (1.0% of rdg ± 3 digits)
± (1.5% of rdg ± 3 digits)
Accuracy
± (0.1% of rdg ± 3 digits)
Accuracy
± (0.5% of rdg ± 3 digits)
± (0.5% of rdg ± 2 digits)
± (1.5% of rdg ± 3 digits)
Accuracy
1.0% uncertainty
Accuracy
Open circuit voltage approx. 0.5V
VELLEMAN