WARNING
!
Turning off wall switch is not sufficient. To avoid possible
electrical shock, be sure electricity is turned off at the
main fuse box before wiring. All wiring must be in
accordance with National and Local codes and the ceiling
fan must be properly grounded as a precaution against
possible electrical shock.
6.1
This control is designed to operate only one ceiling fan
Before disconnecting power, ensure that the fan is set at
the highest speed.
NOTE: Electric connections should be in accordance
with the National Electrical Codes and all Local
Codes. Before starting, disconnect power to the
circuit at the fuse box or circuit breaker panel.
Remove the faceplate and screws from the existing wall
switch. Pull switch out from wall outlet box.
Disconnect the wire from the existing fan wall switch
(Figure 22).
6.2
Slide the Fan Control to the OFF position (0).
Connect one BLACK wire from the Fan Control to the
facility active BLACK wire with a wire connector (provided)
(Figure 23).
Connect the other BLACK wire from the Fan Control to the
outlet box active BLACK wire with a wire connector
(provided with control) (Figure 23).
NOTE: Use wire connectors (supplied) to secure
electrical connections.
6. Installing the Wall Control
All manuals and user guides at all-guides.com
SCREWS
Figure 22
TO NEUTRAL
4
3
2
1
0
Figure 23
15
WALL
WALL
OUTLET
SWITCH
BOX
FACEPLATE
TO FAN MOTOR LOAD
BLACK
BLACK
BLACK
BLACK
120VAC
SOURCE
emersonfans.com
Please contact 1-800-654-3545 for further assistance