The earth has to be connected!
OPERATION
After you connected the device to the mains, the UV-tube lamp needs 3-4 minutes warm-up time until it
reaches full lighting output.
With the ON/OFF-switch, you can switch the device on and off.
CLEANING AND MAINTENANCE
The operator has to make sure that the installation is inspected once a year.
The following points have to be considered during the inspection:
1) All screws used for installing the devices or parts of the device have to be tighly connected and must not
be corroded.
2) There must not be any deformations on housings, fixations and installation spots (ceiling, suspension,
trussing).
3) The electric power supply cables must not show any damages, material fatigue (e.g. porous cables) or
sediments.
We recommend a frequent cleaning of the device. Please use a moist, lint-free cloth. Never use alcohol or
solvents!
The interior of the device should be cleaned at least annually using a vacuum-cleaner or an air-jet.
There are no serviceable parts inside the device except for the lamp. Maintenance and service operations
are only to be carried out by authorized dealers.
Should you need any spare parts, please use genuine parts.
If the power supply cable of this device becomes damaged, it has to be replaced by authorized dealers only
in order to avoid hazards.
Should you have further questions, please contact your dealer.
TECHNICAL SPECIFICATIONS
Power supply:
Power consumption:
Dimensions (LxWxH):
Weight:
Fitting lamp:
Maximum ambient temperature t
Maximum housing temperature t
(steady state):
Please note: Every information is subject to change without prior notice. 20.02.2003 ©
DANGER TO LIFE!
Disconnect from mains before starting maintenance operation!
230 V AC, 50 Hz ~
100 W
620 x 110 x 40 mm
2 kg
UV-tube up to max. 20 W/60 cm UV-tube up to max. 40 W/120 cm
:
45° C
a
60° C
B
18 W/60 cm
14/26
36 W/120 cm
230 V AC, 50 Hz ~
100 W
1230 x 110 x 40 mm
4 kg
45° C
60° C
51101510_V_1_0_4713.DOC