Connection with the mains
Connect the device to the mains via optional power supply cable.
The occupation of the connection-cables is as follows:
Cable
Pin
Brown
Live
Blue
Neutral
Yellow/Green
Earth
The earth has to be connected!
If the device will be directly connected with the local power supply network, a disconnection switch with a
minimum opening of 3 mm at every pole has to be included in the permanent electrical installation.
The device must only be connected with an electric installation carried out in compliance with the IEC-
standards. The electric installation must be equipped with a Residual Current Device (RCD) with a maximum
fault current of 30 mA.
Attention: After every 16 PS-144 spots, the fixtures must have a renewed connection with the power mains.
Attention: A booster must be installed after every 16 PS-144 spots for signal enforcement.