Descargar Imprimir esta página

Moog D941 Serie Instrucciones De Servicio página 3

Ocultar thumbs Ver también para D941 Serie:

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

3 Installation
NOTICE
Damage due to dirt, moisture and ozone/UV effects
• Storage outside or under the wrong climatic conditions can
cause corrosion and other damage to the valve. Conden-
sation due to temperature fluctuations can result in elec-
tronic malfunctions.
 In the case of intermediate storage, observe the follow-
ing storage conditions:
• Recommended ambient temperature: +15 to +25 °C
(+60 to +78 °F), permissible temperature: –40 to
+80 °C (–40 to +176 °F), temperature fluctuation:
< 10 °C (18 °F)
• Relative humidity: < 65 % not condensing
• Ensure there are minimal vibration and shock where
valves are stored
 Following transport or storage, wait until the valves have
reached ambient temperature before starting up.
• Dirt and moisture can enter the valve through openings
and cause damage. Seals can be damaged due to the
effects of ozone and UV.
 During storage and transport, seal connectors with dust
protection caps and install the shipping plate on the
mounting surface.
 Remove dust protection caps and shipping plate only
shortly before mounting the valves and keep packaging
materials for future storage and transport.
 Seal with protection caps any valve connectors that are
not used in operation (without mating connector).
Compare model number and type with that specified on hy-
draulic schematic. The valve can be mounted in any position,
fixed or movable. The venting screw has to point upwards.
Mounting
surface:
(< 0.01 mm (0.00004 in) over 100 mm (3.94 in)) and finish
(R
< 0.8 µm). Care must be taken to ensure that contamina-
a
tion does not enter the hydraulic system, all work areas must
be clean of surface or air-borne contamination.
Mounting: Socket head screws (grade 10.9) according to
EN ISO 4762, torque diagonally alternating.
Pattern to
Series
ISO 4401
D941
05-05-0-05
D942
07-07-0-05
D943/4
08-08-0-05
4 Pilot Mode and Maximum Pressures
Pilot mode: Pay attention to the hydraulic connection scheme
and to the mounting pattern of the hydraulic manifold. Pay at-
tention to the hydraulic schematic on the valve nameplate and
to the type designation defining the pilot mode.
Maximum pilot and operating pressure (p
plate.
5 Electrical Connection
Electrical safety: The protective conductor connection is con-
nected to the electronics housing or valve body. The insulation
materials employed are designed for use in the safety extra-
low voltage range. The field bus circuit connections are only
functionally galvanically isolated from the other connected cir-
cuits.
To comply with safety regulations requires isolation from the
mains according to EN 61558-1 and EN 61558-2-6 and limiting
all voltages according to EN 60204-1. We recommend using
SELV/PELV power supplies.
Rated signal: See nameplate.
External fuse per valve: 0.5 A time lag
Page 2/3
All manuals and user guides at all-guides.com
Check
for
flatness
Torque
Socket
[Nm]
head screw
Pcs.
(lbf in)
M6 x 60
4
11
M10 x 60
4
54
M6 x 55
2
11
M12 x 75
6
94
, p
): See name-
X
P
Valve phasing: A positive signal (4–5) causes valve opening
PA.
Connector wiring: See wiring schematic tag attached to elec-
tronics housing, or refer to the catalog or the installation draw-
ing.
Connection: Signal lines shielded, shielding connected at
both ends and additionally connected to reference potential
(0 V) at the control side (to improve EMC). Connect the protec-
tive conductor.
Observe technical note TN 353.
6 Hydraulic System Start Up
Pay attention to the pressure setting, the venting instructions,
the fail-safe functions and the alarm messages!
7 Venting
WARNING
Hydraulic fluid squirting out
Hydraulic fluid squirting out under high pressure or
parts falling off can cause serious personal injuries,
burns and fires.
 Only vent the valve and the actuator at a low sys-
tem pressure of max. 10 bar (145 psi).
 Carefully open the venting screw by approx. one
revolution.
8 Null Adjustment
WARNING
Unsafe state of the machine due to wrong posi-
tion of the valve's spool.
A wrong position of the valve's spool may result in
undefined sequences of motion.
 With valves with fail-safe function, the null position
must not be altered.
The null adjustment of the valve and further parameterizations
can be done via the field bus.
9 Maintenance
Except for a regular visual inspection for exterior leakage and
filter change, no maintenance work on the valves is required.
Changing the filter: The installed filter protects internal ori-
fices and nozzles against coarse particle contamination. The
valve response time will increase as contamination increases.
The filters located below the filter cover at the side may be re-
placed by the customer.
NOTICE
Changing the filter
Cleaning serves no purpose.
NOTICE
Fluid flow through the filter disk (2) is from inside to outside
leaving particles behind the filter disk (2) and cannot be seen
from the outside after removing the filter cover (4).
NOTICE
 Before beginning work, clean the outside of the valve
around the filter cover!
Mounting and Installation Notes D941/2/3/4 (B97072-941-001; Version G, 02/15)

Publicidad

loading

Este manual también es adecuado para:

D942 serieD943 serieD944 serie