Descargar Imprimir esta página

Daikin FTX09BXVJU Manual De Instrucciones página 16

Publicidad

Idiomas disponibles

Idiomas disponibles

Class 09/12
[Method of mounting conduit]
● A protection plate is fixed for protection from the high-voltage section.
1) Dismount the stop valve cover by removing the screw.
2) Dismount the protection plate by removing the 2 screws.
3) Dismount the conduit mounting cover by removing the 2 screws.
4) Pass wires through the conduit and secure them with a lock nut.
5) After completing the work, reattach the stop valve cover, the conduit mounting cover, and the protection plate to its
original position.
Shape wires so
L1
that the proctection
plate and conduit
L2
mounting plate fit
securely.
Conduit
mounting
cover
Conduit
Lock nut
Class 18/24
[Method of mounting conduit]
1) Dismount the service lid by removing the screws.
2) Pass wires through the conduit and secure them with a lock nut.
3) After completing the work, reattach the service lid to its original position.
Shape wires so
L1
L1
that the proctection
plate and conduit
mounting plate fit
L2
L2
securely.
ELECTRICAL WIRING CONNECTION
Power supply
terminal block
Power supply
terminal block
Lock nut
Conduit
SIG
1-14
Protection plate
Screws
Conduit
mounting
cover
Screws
Service lid
Screws

Publicidad