Operation
BEFORE FIRST START-UP
BREAk-IN PROCEDURE
(Complete this procedure before using
compressor for the first time. Once
completed, it is not necessary to repeat.)
1. Turn ON/OFF switch (
position (
).
2. Open the tank drain valve.
3. Plug in power cord.
4. Turn ON/OFF switch (
position ( ) and run compressor for
30 minutes.
5. Turn ON/OFF switch (
position (
).
6. Unplug power cord.
7. Close drain valve.
The compressor is now ready for use.
BEFORE EACH START-UP
OPERATING PROCEDURE
1. Turn regulator knob fully counter
clockwise (to the left) to close air
flow.
2. Connect air hose to outlet of
regulator.
3. Turn On/Off Switch (
) to OFF
position (
).
4. Plug in power cord.
5. Turn On/Off Switch (
) to ON
position ( ) and let compressor run
until it reaches automatic shutoff
pressure.
6. Attach tire chuck or tool to end of
hose.
7. Adjust regulator to proper pressure
for tool or tire. Operate tool per
instructions.
As air is depleted from the tank by
use of a tire chuck, tool, etc., the
compressor will restart automatically
at its preset "cut-in" pressure. When
a tool is being used continuously,
the compressor will cycle on and off
automatically.
8. Turn switch to OFF position (
unplug power cord and drain
tank of air when finished using
compressor.
Risk of Bursting! This
compressor is designed
to provide air pressure
up to 200 psi. Most
attachments are designed to
operate at a maximum pressure
of less than 125 psi. DO NOT
adjust the regulator to result in
output pressure greater than the
marked maximum pressure of the
attachment.
Maintenance
Disconnect power
source then release
all pressure from the
system before attempting to
) to OFF
install, service, relocate or perform
any maintenance. Service should be
performed by an authorized service
representative.
) to ON
The compressor should be checked
often for any visible problems and the
following maintenance procedures
should be performed each time the
) to OFF
compressor is used.
ASME SAFETY vALvE
the safety valve!
Figure 3
Check the safety valve by performing
the following steps:
1. Plug the compressor in and run until
shut off pressure is reached (see
Operating Procedure).
2. Wearing safety glasses, pull the ring
on the safety valve (see Figure 3) to
release pressure from compressor
tank. Use your other hand to deflect
fast-moving air from being directed
toward your face.
3. The safety valve should
automatically close at approximately
40 - 50 psi. If the safety valve does
not allow air to be released when
you pull on the ring, or if it does
not close automatically, it MUST be
replaced.
),
Wire
Power cord
Motor cord
Power cord
Motor cord
(✽) When the unit is not in operation
Length of Cord
Gauge
cannot be actuated or it leaks air
after ring is released.
DRAIN TANk
With compressor shut off and pressure
released: Drain moisture from tank by
opening drain valve underneath tank
(See Figure 4).
Figure 4
CLEANING
Turn power OFF and clean dust and dirt
Do not remove or
from motor, tank, air lines and pump
attempt to adjust
cooling fins.
IMPORTANT: Unit should be located as
far from spraying area as hose will allow
to prevent over-spray from clogging air
filter.
AIR FILTER
Check air filter to be sure it is clean.
To service a filter, remove the filter
housing cover. Remove filter and
clean in hot, soapy water (Paper filters
cannot be washed). Rinse and let
dry. Replace air filters that cannot be
cleaned. Place filter back in the housing
base. Replace cover.
LUBRICATION
This is an oilless type compressor
requiring no lubrication.
✽ Wire and Terminal Guide
Color
White
White
Black
Black
Minimum Gauge of Extension Cords
25 feet
14
5
HJ3000 Series
Safety valve must
be replaced if it
Terminal
Hot
Line
No
Load
No
Line
Yes
Load
Yes
50 feet
100 feet
12
10
www.chpower.com