m) After 500 operating hours, check the condition of the motor carbon brushes.
The condition of the carbon brushes should also be checked when the motor
of the device is getting weaker and heats up. Regular inspection and
replacement of the carbon brushes extends the life of the unit. To get to the
carbon brushes:
DISPOSAL OF WASTE APPLIANCES
At the end of its useful life, this product should not be disposed of with normal
household waste but should be taken to a collection point for the recycling of
electrical and electronic equipment. This is indicated by the symbol on the
product, operating instructions or packaging. The materials used in this appliance
are recyclable according to their marking. By reuse, recycling or applying other
forms of use of waste machines, you make a significant contribution to the
protection of our environment.
Your local administration will provide you with information about the appropriate
disposal point for used appliances.
ASSEMBLY DRAWING
MSW-RC-280
When replacing the hydraulic fluid, first drain the used fluid from the
inside of the unit, and then fill it with fresh fluid in the same way as in
the refilling procedure.
Disconnect the unit from the power supply.
Dismantle the rear casing of the unit by removing the screws holding
it.
Locate the carbon brush plugs on both sides.
Unscrew the plugs, remove the carbon brushes and check their
condition - if they are less than 5-6 mm high, replace them.
Install in the reverse order of removal.
Check the operation of the unit "on idle" after attaching new carbon
brushes.