• Safety Code for Portable Air Tools, ANSI B186.1 available from: American National Standards Institute, Inc.; 1430 Broadway;
New York, New York 10018
• State and local regulations
WARNING
• Always wear required personal safety protection in accordance with manufacturer's instructions and local/national
standards while using this tool.
• Do not use a power tool if you are tired or under the influence of drugs, alcohol or medication.
• Read the Materials Safety Data Sheet (MSDS) for the working surface.
• Use the tool with dust extraction. A suitable dust extraction unit will reduce hazardous dust.
• Do not overreach. Keep proper footing and balance at all times.
• Do not wear loose clothing or jewellery. Keep your hair, clothing and gloves away from moving parts.
• Loose clothes, jewellery or long hair can be caught in moving parts.
• If any physical hand/wrist discomfort is experienced, stop working and seek medical attention.
• Hand, wrist and arm injury may result from repetitive work, motion and overexposure to vibrations.
• Do not operate power tools in explosive atmospheres, such as in the presence of flammable liquids, gases or dust.
• The tool is not electrically insulated. Check work area for live electricity, gas pipes, etc. before operation.
CAUTION
• Prevent unintentional starting.
• Remove pad wrench before connecting the tool to the air supply.
• Keep work area clean and well lit.
• Always ensure that the work piece to be sanded is firmly fixed.
• Before changing abrasive always disconnect the air supply.
Additional Safety Warnings
• Read all instructions before using this tool. All operators must be fully trained in usage and safety of this tool.
• All maintenance must be carried out by trained personnel. For service, contact Mirka authorized service centre!
• Always wear required safety equipment (see warnings).
• The operator must be in a secure position and have a firm grip and footing on a solid floor.
• Always ensure that the work piece to be sanded is firmly fixed.
• Check tool, backing pad, hose and fittings regularly for wear.
• Always take care to ensure your safety at work; never carry, store or leave the tool unattended with the air supply
connected.
• Vacuum unit dust collection bag should be cleaned or replaced daily. Dust can be highly combustible. Cleaning or
replacing of bag also assures optimum performance.
• Do not exceed maximum recommended air pressure of 6.2 bar (90 psig).
• Take care to avoid entanglement of the moving parts of the tool with clothing, ties, hair, cleaning rags, etc.
• Keep hands clear of the spinning pad during use.
• If the tool appears to malfunction, remove from use immediately and arrange for service and repair.
• Before changing abrasive always disconnect the air supply. Take care to properly attach and centre the abrasive on the
backing pad.
Technical data
PROS
525NV
Orbit
2.5 mm (3/32")
Vacuum type
Pad size
Ø 125 mm (5")
Product net weight
0.89 kg (2.0 lbs)
Height
102 mm (4")
550CV/NV
580CV/NV
5 mm (3/16")
8 mm (5/16")
Ø 125 mm (5")
Ø 125 mm (5")
0.89 kg (2.0 lbs)
0.91 kg (2.0 lbs)
102 mm (4")
102 mm (4")
625CV/NV
650CV/NV
2.5 mm (3/32")
5 mm (3/16")
Ø 150 mm (6")
Ø 150 mm (6")
0.9 kg (2.0 lbs)
0.93 kg (2.1 lbs)
102 mm (4")
102 mm (4")
Mirka® PROS 150 mm (6"), 125 mm (5")
en (original)
680CV/NV
8 mm (5/16")
Ø 150 mm (6")
0.95 kg (2.1 lbs)
102 mm (4")
51