IMPORTANT: The biggest problem that causes product failure is dirt. Keep it clean and well lubricated to prevent any foreign
body from entering the hydraulic circuit. If you have been exposed to rain, snow and/or sand you must clean it before use.
1. Store in a well-protected area where it is not exposed to corrosive vapours, abrasive dust, or other harmful elements.
2. Lubricate moving parts regularly.
3. Change the oil at least once a year. The pistons should be fully retracted prior to proceeding to check or refill the oil level. The oil
level is correct when it is between the two marks on the rod. Refill as required in accordance with the volume indicated in the table.
IMPORTANT: The use of alcohol or brake fluid can damage the seals and cause the product to fail.
4. Check the product before each use. Take appropriate action if you see any of these occurrences:
a. Damaged hose
b. Damaged structure
5. Keep warning labels and instructions clean and legible. Clean outer parts with mild soap.
Repairs must be carried out in a clean environment by qualified personnel who, through their training and experience, are familiar
with the hydraulic systems used in these appliances.
CAUTION: In order to prevent possible accidents, all inspections, maintenance and repairs must be carried out when
it is not loaded, when it is not in operation.
PROBLEM
It does not lift the load.
Partially raises the load.
Load rises slowly.
Lifts the load but does not hold it.
Leak from hydraulic.
Does not descend.
Slow descent.
10040002001.03.
.20
Jun

PREVENTIVE MAINTENANCE

c. Oil leaks
d. Damaged pistons

TROUBLESHOOTING GUIDE

CAUSE
Discharge is open.
Low level or no oil.
Air in system.
Load is above product capacity.
Discharge valve and/or overpressure
valve not functioning properly.
Too much or too little oil level.
Pump does not work properly.
Leaks from joints.
Hydraulic leaks.
The valves are not working properly.
Air in system.
Damaged joints or rings.
Closed discharge.
Damaged hydraulic inside.
Return spring damaged.
Noise on moving parts.
e. Loose components
f. Modified equipment
SOLUTION
Check that the discharge is closed.
Discharge needs to be cleaned.
Fill with oil and purge the circuit.
Purge the circuit.
The load to be lifted should never exceed the rated
capacity of the jack.
Clean to remove any internal dirt.
Replace hydraulic oil.
Check oil level.
Check pump vessels.
Replace joints.
Check joints.
Inspect valves. Replace if necessary.
Purge the circuit.
Replace joints or rings.
Open discharge. It will be necessary to clean the
discharge.
Send the article to an authorised repair
workshop.
Replace the discharge.
Lubricate moving parts.
EN